667 349<br />

photometry<br />

Determination of the absorption characteristic<br />

of an untreated chlorophyll solution<br />

By simple means it is possible to produce an<br />

alcohol extract from crushed leaves. This untreated<br />

chlorophyll solution may then be subjected to<br />

photometric analysis.<br />

With the aid of the digital spectrophotometer<br />

(> 667 349) it is possible to record a continuous<br />

absorption spectrum; in spite of the presence<br />

of contamination the existence of absorption<br />

peaks in the blue and red ranges can be<br />

detected.<br />

Equipment list<br />

60 LEYBOLD DIDACTIC · GENERAL CATALOGUE CHEMISTRY<br />

667 352<br />

Determination of the absorption characteristic<br />

of an untreated chlorophyll solution<br />

Quantity Description Cat. No.<br />

1 Digital spectral photometer . . .667 349<br />

1 Computer connection cable<br />

with software . . . . . . . . . . . . . .667 352<br />

1 Personal computer<br />

667 349<br />

Digital spectral photometer<br />

The digital spectral photometer is an economical,<br />

easy-to-operate single beam photometer.<br />

The digital display allows the simultaneous indication<br />

of transmission and absorption or concentration<br />

and factor.<br />

The wavelength can also be indicated in both<br />

cases.The filter wheel contains 4 filters each of<br />

which covers a different range of wavelengths.<br />

Specific wavelengths are selected manually<br />

after the appropriate filter has been positioned<br />

in the beam.<br />

The integrated interface allows connection to<br />

the RS 232 interface of a computer. The software<br />

which is accompanying the computer<br />

connection cable (> 667 352 ) allows the<br />

recording of the absorption as a factor of the<br />

concentration, time or wavelength.<br />

The function of a large digital display can be<br />

called up on the monitor.<br />

Wavelength range: 340...900 nm<br />

Resolution: 2.5 nm<br />

Wavelength accuracy: ± 1.0 nm<br />

Photometric stability: ± 0.1 %T<br />

Photometric linearity: ± 0.1 %T<br />

Measurement ranges:<br />

Transmission: 0...100 %<br />

Absorption: 0...1.999<br />

Concentration: 0...199<br />

Factor: 0.1...999<br />

Display:<br />

LED, 4-digit, 7 mm high<br />

Cells:<br />

Round cells,<br />

15 mm external diameter,<br />

100 mm high<br />

Cell holder: 15 mm<br />

Data output: Serial, 9-pin<br />

Voltage supply:<br />

115/230V, 50/60 Hz, switchable<br />

Dimensions: 410 x 210 x 220 mm<br />

Weight: 5.8 kg<br />

Scope of delivery<br />

1 Digital spectral photometer,<br />

including RS 232 interface<br />

2 Round cells<br />

667 352<br />

Computer connection cable<br />

This cable allows the digital spectral photometer<br />

(> 667 349 ) to be connected directly to<br />

the serial interface of a computer. DOS software<br />

is also included in the scope of supply