665 486<br />

CPS flow-through photometer<br />

The CPS flow-through photometer is intended<br />

for use as a detector, e.g.:<br />

· for determining substrate or product concentrations<br />

in biotechnology<br />

· in preparative organic and biochemical<br />

analysis<br />

· with HPLC<br />

The detector utilizes the radiation of a lowpressure<br />

mercury discharge lamp with a UV<br />

component of over 90% at a wavelength of<br />

254 nm. The photosensitive semiconductors<br />

respond selectively to this wavelength, so that<br />

a monochromator is not necessary. To compensate<br />

for variations in the intensity of the light<br />

source, differential measurements are carried<br />

out on two light beams. One beam is passed<br />

through a quartz-glass cell containing the sample<br />

which is to be measured, while the other is<br />

used as the reference beam. The differential<br />

amplifier allows recording of the differential signal<br />

with the standard measuring ranges provided<br />

by most chart recorders or via a computer.<br />

Beam source: Hg discharge lamp<br />

Measurement wavelength: 254 nm<br />

Detector: photocell<br />

Cell: quartz, optical path length 2 mm<br />

Recorder output: 0 ... +2 V<br />

Power supply: 230 V/50 Hz<br />

Dimensions: 100 x 297 x 143 mm<br />

Weight: 2.4 kg<br />

665 485<br />

HPLC pump<br />

Short-stroke electromagnetic pump with Teflon<br />

membrane mounted on a CPS training panel;<br />

stainless steel head with special Teflon diaphragm.<br />

The only limitation for the liquid to<br />

be transported is that it may not contain<br />

any dispersed and coarse impurities. Connections<br />

for Teflon tubing with 1.4 mm diameter.<br />

The pump can be externally controlled via a<br />

TTL input.<br />

Pumping capacity: 60 ... 1300 ml/h<br />

Operating pressure: max. 10 bar<br />

Diaphragm: with steel core and PTFE coating<br />

Connections: for 1.4 mm Teflon tubing<br />

Power rating: 11 W<br />

Mains supply: 230 V/50 Hz<br />

Signal input: TTL, 2 sockets 4 mm<br />

Dimensions: 200 x 297 x 150 mm<br />

Experiment panel: 200 x 297 mm<br />

Weight: 3.5 kg<br />

665 481<br />

chromatography<br />

HPLC support for chromatography columns<br />

CPS training panel for accommodating HPLC<br />

columns (> 665 478 - > 665 4791).Mounting<br />

the columns is extremely easy. They are<br />

simply mounted to the CPS system panel<br />

using clamping devices.<br />

Dimensions: 100 x 297 x 140 mm<br />

Panel: 100 x 297 mm<br />

Weight: 0.5 kg<br />

665 478<br />

Separating column SI 60<br />

Preparative column, silica gel,<br />

particle size 40-63 µm, max. 6 bar/90 psi,<br />

for adsorption chromatography.<br />

Length: 240 mm<br />

Inside diameter: 10 mm<br />

665 4791<br />

RP-18 separating column<br />

Preparative column, reversed phase for distribution<br />

chromatography, particle size 40 -<br />

63 µm, max. 6 bar/90psi.<br />

Length: 240 mm<br />

Inside diameter: 10 mm<br />

665 488<br />

Set of hoses and septa for HPLC<br />

HPLC modules<br />

665 478<br />

665 481<br />

1 Teflon hose (0.8 x 1.5 mm), 2 m long<br />

25 Viton septa (10 x 1 mm)<br />

25 silicone septa (10 x 4 mm)<br />

LEYBOLD DIDACTIC · GENERAL CATALOGUE CHEMISTRY<br />

49