SET.38<br />
of 66<br />
<strong>SEL</strong>-<strong>751A</strong> <strong>Settings</strong> <strong>Sheets</strong><br />
SET PORT p (p = F, 1, 2, 3, or 4) Command<br />
Date________________<br />
Enable Unsolicited Reporting (Y, N)<br />
(Hidden if ECLASSA1 := 0, ECLASSB1 := 0, ECLASSC1 := 0, and<br />
ECLASSV1 := 0)<br />
Enable Unsolicited Reporting at Power-Up (Y, N)<br />
(HiddenifUNSOL1:=N)<br />
Number of Events to Transmit On (1–200)<br />
(HiddenifUNSOL1:=N)<br />
Oldest Event to Tx On (0.0–99999.0 sec)<br />
(HiddenifUNSOL1:=N)<br />
Unsolicited Message Max Retry Attempts (2–10)<br />
(HiddenifUNSOL1:=N)<br />
Unsolicited Message Offline Time-Out (1–5000 sec)<br />
(HiddenifUNSOL1:=N)<br />
UNSOL1 :=<br />
PUNSOL1 :=<br />
NUMEVE1 :=<br />
AGEEVE1 :=<br />
URETRY1 :=<br />
UTIMEO1 :=<br />
Session 2<br />
All Session 2 settings are Hidden if EDNP < 2.<br />
IP Address {zzz.yyy.xxx.www} (15 characters) DNPIP2 :=<br />
Transport Protocol (UDP, TCP) DNPTR2 :=<br />
UDP Response Port (REQ, 1–65534) DNPUDP2 :=<br />
DNP Address to Report to (0–65519) REPADR2 :=<br />
DNP Map (1–3) DNPMAP2 :=<br />
Analog Input Default Variation (1–6) DVARAI2 :=<br />
Class for Binary Event Data (0–3) ECLASSB2 :=<br />
Class for Counter Event Data (0–3) ECLASSC2 :=<br />
Class for Analog Event Data (0–3) ECLASSA2 :=<br />
Currents Scaling Decimal Places (0–3) DECPLA2 :=<br />
Voltages Scaling Decimal Places (0–3) DECPLV2 :=<br />
Misc Data Scaling Decimal Places (0–3) DECPLM2 :=<br />
Amps Reporting Deadband Counts (0–32767)<br />
ANADBA2 :=<br />
(Hidden if ECLASSA2 := 0)<br />
Volts Reporting Deadband Counts (0–32767)<br />
ANADBV2 :=<br />
(Hidden if ECLASSA2 := 0)<br />
Misc Data Reporting Deadband Counts (0–32767)<br />
ANADBM2 :=<br />
(Hidden if ECLASSA2 := 0 and ECLASSC2 := 0)<br />
Minutes for Request Interval (I, M, 1–32767) TIMERQ2 :=<br />
Seconds to Select/Operate Time-Out (0.0–30.0) STIMEO2 :=<br />
Seconds to send Data Link Heartbeat (0–7200)<br />
DNPINA2 :=<br />
(HiddenifDNPTR2:=UDP)<br />
Event Message Confirm Time-Out (1–50 sec)) ETIMEO2 :=<br />
Enable Unsolicited Reporting (Y, N)<br />
(Hidden if ECLASSA2 := 0, ECLASSB2 := 0, ECLASSC2 := 0, and<br />
ECLASSV2 := 0)<br />
Enable Unsolicited Reporting at Power-Up (Y, N)<br />
(HiddenifUNSOL2:=N)<br />
UNSOL2 :=<br />
PUNSOL2 :=<br />
<strong>SEL</strong>-<strong>751A</strong> Relay Instruction Manual Date Code 20090501