SET.40<br />
of 66<br />
<strong>SEL</strong>-<strong>751A</strong> <strong>Settings</strong> <strong>Sheets</strong><br />
SET PORT p (p = F, 1, 2, 3, or 4) Command<br />
Date________________<br />
Unsolicited Message Max Retry Attempts (2–10)<br />
(HiddenifUNSOL3:=N)<br />
Unsolicited Message Offline Time-Out (1–5000 sec)<br />
(HiddenifUNSOL3:=N)<br />
URETRY3 :=<br />
UTIMEO3 :=<br />
PORT 2 (Fiber-Optic Serial Port in Slot B)<br />
(Hidden if E49RTD := EXT or Port 2 Not Included)<br />
PROTOCOL (<strong>SEL</strong>, DNP, MOD, EVMSG, PMU, MBA, MBB,<br />
MB8A, MB8B, MBTA, MBTB)<br />
PROTO :=<br />
Communications<br />
SPEED (300, 1200, 2400, 4800, 9600, 19200, 38400 bps) SPEED :=<br />
DATA BITS (7, 8 bits) (Hidden if PROTO := MOD, DNP, PMU,<br />
EVMSG, or MB_)<br />
PARITY (O, E, N) (Hidden if E49RTD := EXT or if<br />
PROTO := EVMSG, PMU, or MB_)<br />
STOP BITS (1, 2 bits) (Hidden if PROTO := MOD, EVMSG, or<br />
MB_)<br />
PORT TIME-OUT (0–30 min) (Hidden if PROTO := MOD, PMU,<br />
EVMSG, or MB_)<br />
SEND AUTOMESSAGE (Y, N) (Hidden if PROTO := MOD,<br />
DNP, PMU, EVMSG, or MB_)<br />
FAST OP MESSAGES (Y, N) (Hidden if PROTO := MOD, dnp,<br />
pmu, EVMSG, or MB_)<br />
HDWR HANDSHAKING (Y, N) (Hidden if PROTO := MOD,<br />
DNP, <strong>SEL</strong>, PMU, EVMSG, or MB_)<br />
Modbus<br />
MODBUS SLAVE ID (1–247) (Hidden if PROTO := <strong>SEL</strong>,<br />
EVMSG, or MB_)<br />
BITS :=<br />
PARITY :=<br />
STOP :=<br />
T_OUT :=<br />
AUTO :=<br />
FASTOP :=<br />
RTSCTS :=<br />
SLAVEID :=<br />
DNP3 Protocol<br />
(Hidden if PROTO := <strong>SEL</strong>, EVMSG, MB, PMU, or MOD.)<br />
DNP Address (0–65519) DNPADR :=<br />
DNP Address to Report to (0–65519) REPADR1 :=<br />
DNP Map (1–3) DNPMAP1 :=<br />
Analog Input Default Variation (1–6) DVARAI1 :=<br />
Class for Binary Event Data (0–3) ECLASSB1 :=<br />
Class for Counter Event Data (0–3) ECLASSC1 :=<br />
Class for Analog Event Data (0–3) ECLASSA1 :=<br />
Currents Scaling Decimal Places (0–3) DECPLA1 :=<br />
Voltages Scaling Decimal Places (0–3) DECPLV1 :=<br />
Misc Data Scaling Decimal Places (0–3) DECPLM1 :=<br />
Amps Reporting Deadband Counts (0–32767)<br />
(Hidden if ECLASSA1 := 0)<br />
ANADBA1 :=<br />
<strong>SEL</strong>-<strong>751A</strong> Relay Instruction Manual Date Code 20090501