SET.44<br />

of 66<br />

<strong>SEL</strong>-<strong>751A</strong> <strong>Settings</strong> <strong>Sheets</strong><br />

SET PORT p (p = F, 1, 2, 3, or 4) Command<br />

Date________________<br />

MB Receive Default State (8 characters) RXDFLT :=<br />

RMB1 Pickup Debounce Messages (1–8) RMB1PU :=<br />

RMB1 Dropout Debounce Messages (1–8) RMB1DO :=<br />

RMB2 Pickup Debounce Messages (1–8) RMB2PU :=<br />

RMB2 Dropout Debounce Messages (1–8) RMB2DO :=<br />

RMB3 Pickup Debounce Messages (1–8) RMB3PU :=<br />

RMB3 Dropout Debounce Messages (1–8) RMB3DO :=<br />

RMB4 Pickup Debounce Messages (1–8) RMB4PU :=<br />

RMB4 Dropout Debounce Messages (1–8) RMB4DO :=<br />

RMB5 Pickup Debounce Messages (1–8) RMB5PU :=<br />

RMB5 Dropout Debounce Messages (1–8) RMB5DO :=<br />

RMB6 Pickup Debounce Messages (1–8) RMB6PU :=<br />

RMB6 Dropout Debounce Messages (1–8) RMB6DO :=<br />

RMB7 Pickup Debounce Messages (1–8) RMB7PU :=<br />

RMB7 Dropout Debounce Messages (1–8) RMB7DO :=<br />

RMB8 Pickup Debounce Messages (1–8) RMB8PU :=<br />

RMB8 Dropout Debounce Messages (1–8) RMB8DO :=<br />

PORT 4 (EIA-232/485 Port or DeviceNet Port in Slot C)<br />

(Hidden If Option Not Included)<br />

PROTOCOL (<strong>SEL</strong>, DNP, MOD, DNET, EVMSG, PMU,<br />

MBA, MBB, MB8A, MB8B, MBTA, MBTB)<br />

PROTO :=<br />

Interface Select (Hidden if PROTO := DNET)<br />

COMM INTERFACE (232, 485) COMMINF :=<br />

Communications<br />

SPEED (300–38400 bps) (Hidden if PROTO := DNET) SPEED :=<br />

DATA BITS (7, 8 bits)<br />

(Hidden if PROTO := DNP, MOD, PMU, EVMSG, MB_, or DNET)<br />

PARITY (O, E, N)<br />

(HiddenifPROTO:=DNET,EVMSG,PMU,orMB_)<br />

STOP BITS (1, 2 bits)<br />

(Hidden if PROTO := MOD, EVMSG, MB_, or DNET)<br />

PORT TIME-OUT (0–30 min)<br />

(Hidden if PROTO := MOD, EVMSG, MB_, PMU, or DNET)<br />

HDWR HANDSHAKING (Y, N)<br />

(Hidden if COMMINF := 485 or PROTO := MOD, DNP, EVMSG,<br />

MB_, or DNET)<br />

SEND AUTOMESSAGE (Y, N)<br />

(Hidden if PROTO := DNP, MOD, EVMSG, MB_, PMU, or DNET)<br />

FAST OP MESSAGES (Y, N)<br />

(Hidden if PROTO := DNP, MOD, EVMSG, MB_, PMU, or DNET)<br />

BITS :=<br />

PARITY :=<br />

STOP :=<br />

T_OUT :=<br />

RTSCTS :=<br />

AUTO :=<br />

FASTOP :=<br />

<strong>SEL</strong>-<strong>751A</strong> Relay Instruction Manual Date Code 20090501