Quick-Change Installation and Operation Manual<br />

Document #9610-20-1114-05<br />

3.9 Proximity Sensor installation for <strong>TSM</strong> <strong>Tool</strong> Hanger<br />

1. Attach the proximity sensor to the mounting module by screwing the sensor into the bottom of the<br />

mounting module. Tighten to 6 in-lbs.<br />

2. Position the sensor so the sensor face is flush with the surface of the mounting module.<br />

3. Adjust sensor position as needed.<br />

4. Tighten the jam nut on sensor against the mounting module.<br />

5. Attach the sensor cable to the proximity sensor.<br />

Figure 3.10—Proximity Sensor Position for <strong>TSM</strong> <strong>Tool</strong> Hanger<br />

Mounting Module<br />

Proximity Sensor<br />

Jam Nut<br />

Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 • www.ati-ia.com • Email: info@ati-ia.com<br />