07.12.2012 Views

Reaction vessels for vacuum and pressure

Reaction vessels for vacuum and pressure

Reaction vessels for vacuum and pressure

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

98<br />

Thermostats <strong>and</strong> accessories<br />

Thermostat System Layouts<br />

Simplest system<br />

51009.00<br />

10 pole<br />

*** Automatik<br />

Öltemp :<br />

267,5<br />

P1 S0<br />

00:24:58<br />

Heizung 13 %<br />

0110 0100<br />

System with manual cooling, <strong>for</strong> temperatures up to 250 °C<br />

Öltemp<br />

Reaktor<br />

T1<br />

øC<br />

T2<br />

***<br />

1<br />

T1<br />

2 3<br />

START<br />

STOP<br />

4 5 6 C<br />

T2<br />

PAUSE<br />

7 8 9 M<br />

Karl Kurt Juchheim<br />

Laborgeraete GmbH<br />

D-5550 Bernkastel-Kues<br />

INT<br />

ENTER<br />

0<br />

EXT<br />

+ EDIT<br />

-<br />

RESET<br />

EXIT<br />

Netz<br />

55040.00 Reactor<br />

51001.0*<br />

51001.0*<br />

Heat<br />

exchanger<br />

55105.00<br />

Öltemp<br />

Reaktor<br />

***<br />

Öltemp :<br />

P1 S0<br />

00:24:58<br />

T1<br />

øC<br />

T2<br />

Automatik<br />

267,5<br />

Heizung 13 %<br />

0110 0100<br />

***<br />

1 2 3<br />

T1<br />

or<br />

T2<br />

PAUSE<br />

INT 8<br />

ENTER<br />

Karl Kurt Juchheim<br />

0<br />

EXT<br />

EDIT<br />

7<br />

4 5 6 C<br />

9 M<br />

Laborgeraete GmbH<br />

D-5550 Bernkastel-Kues<br />

+<br />

-<br />

RESET<br />

START<br />

STOP<br />

EXIT<br />

Netz<br />

Betrieb<br />

4KW 2KW Motor Übertemp. Motor Niveau<br />

4 2 0 EIN AUS<br />

Heizleistung<br />

JU 90-4<br />

Störung<br />

51008.**<br />

Motor 0<br />

55104.00<br />

Components required:<br />

Cat. no.<br />

Cat. no.<br />

Thermostat 550*0.** or non-programmable controller 5510*.00<br />

Pt100 thermometer (T1) 51009.00 2 hoses 5100*.**<br />

Programmable controller 55105.** Marlotherm heat transfer fluid, 5 Litre 51016.00<br />

50114.00<br />

51001.0*<br />

51009.00<br />

10 pole<br />

55040.00 Reactor<br />

51001.0*<br />

5011*.00<br />

51001.0*<br />

51001.0*<br />

55105.00<br />

50115.00<br />

or<br />

Betrieb<br />

50<br />

4KW 2KW Motor Übertemp. Motor Niveau<br />

100<br />

4 2 0 EIN AUS<br />

Heizleistung<br />

JU 90-4<br />

150<br />

Störung<br />

51008.**<br />

200<br />

X<br />

K1<br />

350<br />

250<br />

300<br />

°C<br />

Motor 0<br />

55104.00<br />

Components required:<br />

Cat. no.<br />

Cat. no.<br />

Thermostat 55040.** 4 hoses 5100*.**<br />

Pt100 thermometer (T1) 51009.00 Three-way ball valve 50114.00<br />

Programmable controller 55105.** Heat exchanger 5011*.00<br />

or non-programmable controller 55104.00 ‘Y’ piece 51015.00<br />

Marlotherm heat transfer fluid, 5 Litre 51016.00<br />

50<br />

100<br />

150<br />

200<br />

XK1<br />

350<br />

250<br />

300<br />

°C