07.12.2012 Views

Reaction vessels for vacuum and pressure

Reaction vessels for vacuum and pressure

Reaction vessels for vacuum and pressure

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

44<br />

Accessories<br />

Thermometers, thermometer pockets <strong>and</strong> holders<br />

Closed thermometer pockets<br />

Threaded M24 x 1.5; thread length 14 mm <strong>for</strong> <strong>vessels</strong> up to 5 litres,<br />

24 mm <strong>for</strong> <strong>vessels</strong> over 5 litres.<br />

Pressure vessel Vacuum vessel<br />

Size EL Cat. no. Size EL Cat. no.<br />

[ltr] [mm] [ltr] [mm]<br />

1 113 20465.21 1 120 20465.01<br />

2 135 20465.22 2+4 155 20465.02<br />

5 169 20465.24 10 234 20465.05<br />

10 204 20465.25 15 330 20465.15<br />

20 334 20465.26 20 362 20465.06<br />

30 354 20465.27 30+40 385 20465.07<br />

50 414 20465.29 50 530 20465.09<br />

Thermometer holders with dip tube<br />

Threaded M24 x 1.5; thread length 14 mm <strong>for</strong> <strong>vessels</strong> up to 5 litres,<br />

24 mm <strong>for</strong> <strong>vessels</strong> over 5 litres.<br />

The dip tube serves to increase the responsiveness of the thermometer<br />

in viscous media. When ordering replacements please state the<br />

vessel size <strong>and</strong> serial number. Pt100 thermometers are listed below.<br />

Thread length 14 mm <strong>for</strong> <strong>vessels</strong> up to 5 litres 20465.40<br />

Thread length 24 mm <strong>for</strong> <strong>vessels</strong> over 5 litres<br />

Thermometer holders without dip tube<br />

20465.41<br />

Threaded M24 x 1.5; thread length 14 mm <strong>for</strong> <strong>vessels</strong> up to 5 litres,<br />

24 mm <strong>for</strong> <strong>vessels</strong> over 5 litres. Pt100 thermometers are listed below.<br />

Thread length 14 mm <strong>for</strong> <strong>vessels</strong> up to 5 litres 20465.50<br />

Thread length 24 mm <strong>for</strong> <strong>vessels</strong> over 5 litres 20465.51<br />

Pt100 resistance thermometers, the Pt100 resistance thermometer<br />

sits in a metal casing with b<strong>and</strong> <strong>and</strong> has a double-coned cable<br />

approxmately 1.6 m long with a 3-pole connector.<br />

Vessel size<br />

To fit thermometer<br />

pockets<br />

To fit thermometer<br />

holders<br />

Pressure vessel [ltr] EL [mm] Cat. no. EL [mm] Cat. no.<br />

1+2 145 52009.04 115 52009.02<br />

5 215 52009.10 190 52009.05<br />

10 335 52009.20 215 52009.10<br />

20 375 52009.30 335 52009.20<br />

30 420 52009.50 375 52009.30<br />

50 420 52009.50 420 52009.50<br />

Vacuum vessel [ltr] EL [mm] Cat. no. EL [mm] Cat. no.<br />

1+2 145 52009.04 115 52009.02<br />

4 190 52009.05 145 52009.04<br />

10 315 52009.15 215 52009.10<br />

15+20 335 52009.20 315 52009.15<br />

30+40 375 52009.30 335 52009.20<br />

50 420 52009.50 420 52009.50<br />

Dip length (EL)<br />

20465.01-29<br />

20465.40<br />

20465.50<br />

52009.02<br />

Dip length (EL)