08.12.2012 Views

Imatest Documentation

Imatest Documentation

Imatest Documentation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Imatest</strong> <strong>Documentation</strong><br />

Light falloff,<br />

vignetting<br />

Noise<br />

Sharpness (MTF)<br />

Veiling glare (lens flare)<br />

plain, uniformly lit surface Lightfall<br />

Step charts such as the Kodak Q-13/Q-14 Stepchart<br />

GretagMacbeth ColorChecker Colorcheck<br />

Slanted-edge (can be printed from Test Charts)<br />

ISO 12233, Applied Image QA-77<br />

Log Frequency chart<br />

Log F-Contrast chart<br />

Star chart<br />

SFR<br />

Rescharts SFR<br />

Log Frequency<br />

Log F-Contrast<br />

Star Chart<br />

SFRplus chart (highly automated) SFRplus<br />

Reflective step chart with "black<br />

hole"<br />

Color moiré Log Frequency<br />

Software artifacts Log F-Contrast<br />

Data compression Log F-Contrast<br />

Dmax (deepest black<br />

tone)<br />

Color gamut<br />

Sorted by module<br />

Modules are listed on the Tour page.<br />

Custom test chart printed from<br />

file,<br />

scanned on profiled flatbed<br />

scanner<br />

Stepchart<br />

Log<br />

Frequency<br />

Log<br />

F-Contrast<br />

Log<br />

F-Contrast<br />

Prints<br />

Print Test<br />

Part of Rescharts<br />

Part of Rescharts<br />

Best: Screen Patterns with LCD flat<br />

screen.<br />

Printable by Test Charts<br />

Printed on photographic media<br />

Printable by Test Charts<br />

Printable by Test Charts<br />

'' or purchase from Image Engineering<br />

Printable or purchase from the <strong>Imatest</strong><br />

store<br />

Not yet fully supported<br />

Gamutvision extracts these properties from ICC<br />

profiles.<br />

Module Quality factor Charts Comments<br />

Colorcheck<br />

Color accuracy, Tonal<br />

response, Contrast,<br />

GretagMacbeth ColorChecker<br />

Distortion Lens distortion Square or rectangular grid<br />

Lightfall Light falloff, vignetting plain, uniformly lit surface<br />

Multicharts<br />

SFR,<br />

Rescharts<br />

SFR<br />

SFRplus<br />

Stepchart<br />

Dynamic<br />

Range<br />

Print Test<br />

Log<br />

Frequency<br />

Log<br />

F-Contrast<br />

Color accuracy, Tonal<br />

response, Contrast<br />

Sharpness (MTF), Lateral<br />

chromatic aberration<br />

Sharpness (MTF), Lateral<br />

chromatic aberration, Tonal<br />

response, Lens distortion<br />

Tonal response, Contrast,<br />

Noise, Dynamic range,<br />

Exposure accuracy, Veiling<br />

glare (lens flare)<br />

(Postprocessor for<br />

Stepchart) Tonal response,<br />

Dynamic range<br />

Dmax (deepest black tone),<br />

Color gamut<br />

Sharpness (MTF), Color<br />

moiré<br />

Sharpness (MTF), Software<br />

artifacts<br />

GretagMacbeth ColorChecker, IT8.7,<br />

ColorChecker SG, Step charts, special<br />

charts: ISO-16067-1, QA-62, EIA Grayscale,<br />

ISO-14524 OECF, ISO-15739 Noise,<br />

20-patch OECF charts<br />

Slanted-edge (printable by Test Charts), ISO<br />

12233, Applied Image QA-77<br />

SFRplus chart<br />

Step charts, Special charts: ISO-16067-1,<br />

QA-62, EIA Grayscale, ISO-14524 OECF,<br />

ISO-15739 Noise, 20-patch OECF charts<br />

Reflective step charts such as the Kodak<br />

Q-14/Q-14.<br />

Custom test chart printed from file, scanned on<br />

profiled flatbed scanner<br />

Log Frequency (can also use Log<br />

Frequency-Contrast chart)<br />

ColorChecker SG, Step charts,<br />

special charts: <strong>Imatest</strong> Master only<br />

Also measures Subjective Quality<br />

Factor (SQF).<br />

Highly automated module: no manual<br />

ROI selection. Chart available from<br />

the <strong>Imatest</strong> store.<br />

Special charts in <strong>Imatest</strong> Master<br />

only. Transmissive charts such as the<br />

Stouffer T4110 recommended for<br />

DR.<br />

Usually more convenient than<br />

Stepchart for measuring DR<br />

because it doesn't require a<br />

transmission chart, special light<br />

source, and darkened room.<br />

Gamutvision extracts these<br />

properties from ICC profiles.<br />

Part of Rescharts<br />

Log Frequency-Contrast Part of Rescharts<br />

Star Chart Sharpness (MTF) Star chart Part of Rescharts<br />

422 of 451

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!