19.07.2017 Views

ServiceManual

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ToC SERVICE MANUAL MARINE ENGINES<br />

ELECTRICAL SYSTEM<br />

Function "ADJUSt"<br />

When selecting the function "ADJUST", the rpm.<br />

display may be adjusted between 30 and 100 % of<br />

the measuring range.<br />

Using a reference rpm meter (manual rpm meter),<br />

the rpm indicator is compared.<br />

Fine adjustment requires two persons, one to operate<br />

the instrument and the other one to operate the<br />

manual rpm meter on the axis of the engine's<br />

crankshaft. Extreme caution is required! Do not wear<br />

loose clothing!<br />

When the function ADJUSt is selected, UP or dn (UP<br />

or DOWN) appears in alternation on the display after<br />

approx. 3 seconds.<br />

If, for example, the key is pressed and held down<br />

when UP is displayed, the pointer deflection changes<br />

upwards (for "dn" analogously downwards).<br />

If you release the key for 2 seconds and then press<br />

it again, the pointer deflection changes downwards.<br />

At the beginning, the pointer deflection changes very<br />

slowly which permits a very precise fine adjustment.<br />

With a short release of the key, the procedure is<br />

repeated. With a longer pressing of the key, the<br />

pointer deflection will change faster. Release the key<br />

as soon as the fine adjustment corresponds to the<br />

reference rpm. The display then changes to counting<br />

of running-time. Fine adjustment is completed.<br />

07.13 ill.4<br />

Fine Adjustment:<br />

During normal operation of the indicator, a fine<br />

adjustment is possible by using the key. The<br />

adjustment range is +/- 20 % of the actual reading.<br />

Press the key, with voltage supply on.<br />

On the display appears A 0.0<br />

By pressing and holding the key, the adjustment<br />

factor increases in steps of 0,5%.<br />

If you release the key for 2 seconds and then press<br />

it again, the adjustment factor decreases in steps of<br />

0,5%.<br />

If the key is not pressed for more than 5 seconds, the<br />

adjustment factor will be stored and the indicator<br />

switches back to the normal running-time display.<br />

07.13 ill.5<br />

Z001019/0_6_July 2008 Page ELECTRICAL SYSTEM - 69