COGNEX DM100_200 ControlCommands - Bci GmbH
COGNEX DM100_200 ControlCommands - Bci GmbH
COGNEX DM100_200 ControlCommands - Bci GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
DMCC Overview<br />
SET|GET FORMAT.MULTICODE-<br />
DELIMITER<br />
Data Formatting Tokens<br />
General Tokens<br />
type<br />
[0-5]<br />
0: none<br />
1: space<br />
2: comma<br />
3: tab<br />
4: label<br />
5: xml<br />
Data Formatting<br />
Delimiter<br />
Sets the delimiter<br />
between codes in a<br />
multicode result.<br />
<strong>DM100</strong> series and<br />
DM<strong>200</strong> series only<br />
SET|GET FORMAT.ADVANCED state [ON|OFF] enable/disable Enable Data<br />
Formatting Advanced<br />
Mode<br />
Advanced Mode<br />
Formatting Enables:<br />
Regexp Pattern<br />
Substitution<br />
SET|GET FORMAT.REGEXP string regular expression<br />
string<br />
SET|GET FORMAT.DISCARD-<br />
UNMATCHED<br />
Data Formatting<br />
Regular Expression<br />
Requires Data<br />
Formatting Advanced<br />
Mode Enabled.<br />
See the Overview topic<br />
for formatting<br />
requirements for the<br />
string argument.<br />
state [ON|OFF] enable/disable Data Formatting<br />
Discard Unmatched<br />
Data<br />
SET|GET DVALID.GS1-FORMAT string GS1 format string Set GS1 format string<br />
Token Description<br />
Sub-string<br />
Full String<br />
Decode Time<br />
Trigger Time<br />
Symbology<br />
Symbology Identifier<br />
Code Position<br />
CR/LF<br />
TAB<br />
SP<br />
Module Size<br />
Contrast<br />
Unused Error Correction<br />
Code Orientation<br />
Total Reads<br />
Total No-Reads<br />
Total Triggers<br />
Missed Triggers<br />
Trigger Index<br />
Consecutive Bad Reads<br />
Custom Event Count 0<br />
file://C:\Dokumente und Einstellungen\schiermann\Lokale Einstellungen\Temp\~hh7...<br />
Page 14 of 24<br />
27.12.2010