DMCC Overview<br />
SET|GET CQ.METRICS metric<br />
Technology Preview<br />
DMCC Commands marked with are pre-release documentation. These functions are provided as is in DataMan<br />
Software version 3.5. Future releases may change syntax or remove functionality altogether.<br />
I/O Commands<br />
[0-3]<br />
0: AIM-DPM<br />
1: ISO/IEC<br />
15415<br />
2: AS9132<br />
Laser-etch<br />
3: AS9132<br />
Dot-peen<br />
the Verification Feature<br />
Key<br />
Code Quality Enabled<br />
Metrics<br />
SET|GET CQ.PROCESSM state [ON|OFF] enable/disable Code Quality Process<br />
Control Metrics<br />
SET|GET CQ.UNITS option<br />
[0-3]<br />
0: mils<br />
1: mm<br />
2: inches<br />
3: pixels<br />
Code Quality Units<br />
GET CQ.CALIB-DATE Device Code Quality<br />
Calibration Date<br />
SET|GET CQ.ILLUMINATION illuminationoption<br />
state<br />
SET|GET CQ.MINPASS metric<br />
DataMan Control Commands Documentation 3.5<br />
min-pass<br />
[0-4]<br />
[ON|OFF]<br />
[0-1]<br />
[0-4]<br />
0: Direct on<br />
axis<br />
1: 30-deg All<br />
Quadrants<br />
2: 30-deg E-<br />
W Quadrants<br />
3: 30-deg N-S<br />
Quadrants<br />
4: Custom<br />
enable/disable<br />
0: AIM-DPM<br />
1: ISO/IEC<br />
15415<br />
0: F<br />
1: D<br />
2: C<br />
3: B<br />
4: A<br />
Code Quality<br />
Illumination Option<br />
DM7500 Series does not<br />
support Direct-on-axis<br />
Code Quality<br />
illumination.<br />
Code Quality Minimum<br />
Passing Grade<br />
Determines the<br />
threshold for "validation<br />
failure action" including<br />
beep and configured line<br />
output.<br />
Set/Get Command Arguments Range Meaning Description<br />
SET|GET DECODER.TIMEOUT ms [0-<br />
10000]<br />
SET|GET BEEP.GOOD repetition<br />
level<br />
SET|GET BEEP.NO-READ repetition<br />
level<br />
[0-3]<br />
[0-2]<br />
[0-3]<br />
[0-2]<br />
milliseconds Decoder Timeout<br />
Maximum allowed<br />
decode time.<br />
<strong>DM100</strong> series and<br />
DM<strong>200</strong> series only.<br />
number of<br />
beeps<br />
0: Lo pitch<br />
1: Med pitch<br />
2: Hi pitch<br />
number of<br />
beeps<br />
0: Lo pitch<br />
1: Med pitch<br />
2: Hi pitch<br />
Good Read Beep<br />
Settings<br />
Page 18 of 24<br />
No-Read Beep Settings<br />
SET|GET BEEP.DATAVALID-FAIL repetition [0-3] number of Data Validation Failure<br />