DMCC Overview<br />

SET|GET CQ.METRICS metric<br />

Technology Preview<br />

DMCC Commands marked with are pre-release documentation. These functions are provided as is in DataMan<br />

Software version 3.5. Future releases may change syntax or remove functionality altogether.<br />

I/O Commands<br />

[0-3]<br />

0: AIM-DPM<br />

1: ISO/IEC<br />

15415<br />

2: AS9132<br />

Laser-etch<br />

3: AS9132<br />

Dot-peen<br />

the Verification Feature<br />

Key<br />

Code Quality Enabled<br />

Metrics<br />

SET|GET CQ.PROCESSM state [ON|OFF] enable/disable Code Quality Process<br />

Control Metrics<br />

SET|GET CQ.UNITS option<br />

[0-3]<br />

0: mils<br />

1: mm<br />

2: inches<br />

3: pixels<br />

Code Quality Units<br />

GET CQ.CALIB-DATE Device Code Quality<br />

Calibration Date<br />

SET|GET CQ.ILLUMINATION illuminationoption<br />

state<br />

SET|GET CQ.MINPASS metric<br />

DataMan Control Commands Documentation 3.5<br />

min-pass<br />

[0-4]<br />

[ON|OFF]<br />

[0-1]<br />

[0-4]<br />

0: Direct on<br />

axis<br />

1: 30-deg All<br />

Quadrants<br />

2: 30-deg E-<br />

W Quadrants<br />

3: 30-deg N-S<br />

Quadrants<br />

4: Custom<br />

enable/disable<br />

0: AIM-DPM<br />

1: ISO/IEC<br />

15415<br />

0: F<br />

1: D<br />

2: C<br />

3: B<br />

4: A<br />

Code Quality<br />

Illumination Option<br />

DM7500 Series does not<br />

support Direct-on-axis<br />

Code Quality<br />

illumination.<br />

Code Quality Minimum<br />

Passing Grade<br />

Determines the<br />

threshold for "validation<br />

failure action" including<br />

beep and configured line<br />

output.<br />

Set/Get Command Arguments Range Meaning Description<br />

SET|GET DECODER.TIMEOUT ms [0-<br />

10000]<br />

SET|GET BEEP.GOOD repetition<br />

level<br />

SET|GET BEEP.NO-READ repetition<br />

level<br />

[0-3]<br />

[0-2]<br />

[0-3]<br />

[0-2]<br />

milliseconds Decoder Timeout<br />

Maximum allowed<br />

decode time.<br />

<strong>DM100</strong> series and<br />

DM<strong>200</strong> series only.<br />

number of<br />

beeps<br />

0: Lo pitch<br />

1: Med pitch<br />

2: Hi pitch<br />

number of<br />

beeps<br />

0: Lo pitch<br />

1: Med pitch<br />

2: Hi pitch<br />

Good Read Beep<br />

Settings<br />

Page 18 of 24<br />

No-Read Beep Settings<br />

SET|GET BEEP.DATAVALID-FAIL repetition [0-3] number of Data Validation Failure<br />

file://C:\Dokumente und Einstellungen\schiermann\Lokale Einstellungen\Temp\~hh7...<br />