COGNEX DM100_200 ControlCommands - Bci GmbH
COGNEX DM100_200 ControlCommands - Bci GmbH
COGNEX DM100_200 ControlCommands - Bci GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
DMCC Overview<br />
SET|GET TELNET.PORT value [0-<br />
65535]<br />
Technology Preview<br />
DMCC Commands marked with are pre-release documentation. These functions are provided as is in DataMan<br />
Software version 3.5. Future releases may change syntax or remove functionality altogether.<br />
Cognex Corporation assumes no responsibility for the use or reliability of its software on equipment that is not<br />
supplied by Cognex Corporation. Cognex Corporation makes no warranties, either express or implied, regarding<br />
the described software, its merchantability or its fitness for any particular purpose.<br />
The information in this document is subject to change without notice and should not be construed as a<br />
commitment by Cognex Corporation. Cognex Corporation is not responsible for any errors that may be present<br />
in either this document or the associated software.<br />
Copyright © 2010 Cognex Corporation All Rights Reserved<br />
content with<br />
result.<br />
file will be created if it<br />
does not exist.<br />
DM<strong>200</strong> series only<br />
Telnet server TCP port<br />
on reader.<br />
DM<strong>200</strong> series only<br />
SET|GET CUSTOM-CMD.TRIGGER state [ON|OFF] enable/disable Indicates if reader will<br />
respond to the<br />
TRIGGER-ON or<br />
TRIGGER-OFF string.<br />
SET|GET CUSTOM-CMD.TRIGGER-<br />
ON<br />
SET|GET CUSTOM-CMD.TRIGGER-<br />
OFF<br />
string String that will start a<br />
trigger.<br />
See the Overview topic<br />
for formatting<br />
requirements for the<br />
string argument.<br />
string String that will stop a<br />
trigger.<br />
See the Overview topic<br />
for formatting<br />
requirements for the<br />
string argument.<br />
SET|GET CUSTOM-CMD.ECHO state [ON|OFF] enable/disable Indicates if characters<br />
received between a<br />
COMMAND-HEADER and<br />
COMMAND-FOOTER are<br />
echoed.<br />
SET|GET CUSTOM-<br />
CMD.COMMAND-HEADER<br />
SET|GET CUSTOM-<br />
CMD.COMMAND-FOOTER<br />
string Start of the string to be<br />
echoed.<br />
string End of the string to be<br />
echoed.<br />
See the Overview topic<br />
for formatting<br />
requirements for the<br />
string argument.<br />
SET|GET INTER-MESSAGE.DELAY value [0-1000] milliseconds Transmission delay<br />
between buffered read<br />
strings.<br />
DM7550 Series only<br />
SET|GET COM.WAKEUP state [ON|OFF] enable/disable Wakeup Message<br />
SET|GET PROTOCOL mode<br />
DataMan Control Commands Documentation 3.5<br />
Copyright Information<br />
[0-1] 0: DMCC-only<br />
1: Legacy<br />
Mode<br />
Page 22 of 24<br />
This document may not be copied in whole or in part, nor transferred to any other media or language, without<br />
file://C:\Dokumente und Einstellungen\schiermann\Lokale Einstellungen\Temp\~hh7...<br />
27.12.2010