Passive <strong>interface</strong>s for general applications<br />
RS SD - Interface for SUB-D connector in accordance with IEC 60807-2 / DIN 41652<br />
RS SD - Interface for SUB-D connector in accordance<br />
with IEC 60807-2 / DIN 41652<br />
Interface for SUB-D connector in accordance with<br />
IEC 60807-2 / DIN41652.<br />
• 1:1 connection<br />
• 9 to 50 poles<br />
• Screw or tension clamp connection<br />
RSSD Z<br />
RSSD S<br />
1 2 3 4 N<br />
1 2 3 4 N<br />
D<br />
1 2 3 4 N<br />
N: Number of poles<br />
1 2 3 4 N<br />
N: Number of poles<br />
Technical data<br />
Connection data<br />
Connection on control side<br />
Connection (field side)<br />
Rated data<br />
Operating voltage<br />
Operating current per connection<br />
General data<br />
Ambient temperature (operational)<br />
Storage temperature<br />
Approvals<br />
Insulation coordination (EN 50178)<br />
Rated insulation voltage<br />
Surge voltage category<br />
Pollution severity level<br />
Pulse voltage test (1,2/50μs)<br />
Dimensions<br />
Clamping range, min./max. (field)<br />
Mounting rail<br />
Width x height<br />
Note<br />
D-sub connectors, acc. to IEC 60807 / DIN 41652<br />
LM2NZF 5.08mm<br />
100 V<br />
1.5 A<br />
0...55°C<br />
-40...70 °C<br />
CE; EAC<br />
100 V<br />
II<br />
2<br />
0.8 kV<br />
0.13 mm² / 2.5 mm²<br />
TS 35, TS 32<br />
87 mm / 63.6 mm<br />
D-sub connectors, acc. to IEC 60807 / DIN 41652<br />
LP2N 5.08mm<br />
100 V<br />
1.5 A<br />
0...55°C<br />
-40...70 °C<br />
CE; EAC<br />
100 V<br />
II<br />
2<br />
0.8 kV<br />
0.13 mm² / 6 mm²<br />
TS 35, TS 32<br />
87 mm / 76 mm<br />
Ordering data<br />
9-pole male connector<br />
15-pole male connector<br />
25-pole male connector<br />
37-pole male connector<br />
50-pole male connector<br />
9-pole female connector<br />
15-pole female connector<br />
25-pole female connector<br />
37-pole female connector<br />
50-pole female connector<br />
Type Length Order No.<br />
RS SD9 SZ 45 mm 8537260000<br />
RS SD15 SZ 60 mm 8537390000<br />
RS SD25 SZ 80 mm 8537370000<br />
RS SD37 SZ 110 mm 8537240000<br />
RS SD50 SZ 145 mm 8537350000<br />
RS SD9 BZ 45 mm 8537320000<br />
RS SD15 BZ 60 mm 8537400000<br />
RS SD25 BZ 80 mm 8537380000<br />
RS SD37 BZ 110 mm 8537250000<br />
RS SD50 BZ 87 mm 8537360000<br />
Type Length Order No.<br />
RS SD9S UNC 4.40 LP2N 45 mm 8003901001<br />
RS SD15S UNC 4.40 LP2N 60 mm 8005201001<br />
RS SD25S UNC 4.40 LP2N 80 mm 8005181001<br />
RS SD37S UNC 4.40 LP2N 110 mm 8003881001<br />
RS SD50S UNC 4.40 LP2N 154 mm 8005161001<br />
RS SD9B UNC 4.40 LP2N 45 mm 8003911001<br />
RS SD15B UNC 4.40 LP2N 60 mm 8005211001<br />
RS SD25B UNC 4.40 LP2N 80 mm 8005191001<br />
RS SD37B UNC 4.40 LP2N 110 mm 8003891001<br />
RS SD50B UNC 4.40 LP2N 154 mm 8005171001<br />
Note<br />
Accessories<br />
Note<br />
Refer to the „Universal <strong>cables</strong> PAC-UNIV“ section in chapter F<br />
Refer to the „Universal <strong>cables</strong> PAC-UNIV“ section in chapter F<br />
D.8 2021570000