Isolated Interfaces <strong>and</strong> solutions for general<br />
applications<br />
TERMSERIES <strong>adapters</strong><br />
TERMSERIES <strong>adapters</strong><br />
• Suitable for input <strong>and</strong> output logic<br />
• Version for 12.8mm TERMSERIES base<br />
• Supply connections (PUSH IN) in double execution for<br />
supply voltage bridging<br />
• User-friendly <strong>and</strong> unmistakable marking<br />
• 10-pin connector according to DIN EN 60603-13<br />
TIAL F10<br />
Potential change-over switch<br />
<br />
<br />
The potential change-over switch is located between contact rows of<br />
the TERMSERIES adaptor. It is used to switch the potential of the lower<br />
contact row to “+” or “-” potential of the supply voltage.<br />
<br />
<br />
<br />
<br />
<br />
<br />
Installation input<br />
E<br />
Technical data<br />
Supply<br />
Supply voltage<br />
Status display<br />
Signals<br />
Rated voltage<br />
Voltage, max.<br />
Rated current (per signal path)<br />
Current (per signal path), max.<br />
Total current of all signals, max.<br />
Number of signal paths<br />
Connection data (supply)<br />
Wire connection method<br />
Clamping range, rated connection, min.<br />
Clamping range, rated connection, max.<br />
Number of terminals<br />
Connection data (signal)<br />
Plug type<br />
General data<br />
Ambient temperature (operational)<br />
Storage temperature<br />
Humidity<br />
UL 94 flammability rating<br />
Approvals<br />
Insulation coordination<br />
Pollution degree<br />
Overvoltage category<br />
Impulse withst<strong>and</strong> voltage<br />
Rated voltage<br />
Protection degree<br />
24 V DC ± 20 %<br />
Green LED<br />
24 V DC<br />
30 V DC<br />
125 mA<br />
1 A<br />
1 A<br />
8<br />
PUSH IN<br />
0.13 mm²<br />
1.5 mm²<br />
4 (+,+,−,−)<br />
10-pole plug according to DIN EN 60603-13, long locking lever<br />
-40 °C...60 °C<br />
-40 °C...85 °C<br />
5...95% (indoor), T u<br />
= 40°C, no condensation<br />
V-0<br />
CE; cULus; GL<br />
2<br />
III<br />
1.5 kV<br />
32 V<br />
IP 20 in installed condition<br />
A1 +<br />
24V<br />
TOS<br />
TRS<br />
14 11 12 A1 A2<br />
24V<br />
14<br />
A2 -<br />
A1 +<br />
24V<br />
TOS<br />
TRS<br />
14 11 A1 A2<br />
14 11 12 A1 A2<br />
24V<br />
Figure 1a<br />
Figure 1b<br />
NO<br />
14<br />
COM<br />
1122770000<br />
TRS 24VDC 1CO<br />
Figure 1a: Positive-switching logic: Potential change-over<br />
switch to “-”, installation on 24 V DC input (A1/A2).<br />
Figure 1b: Negative-switching logic: Potential change-over<br />
switch to “+”, installation on 24 V UC input (A1/A2).<br />
Installation output<br />
14 11 A1 A2<br />
NO<br />
11<br />
NC<br />
A2 -<br />
11<br />
12<br />
12<br />
NC<br />
COM<br />
1122770000<br />
TRS 24VDC 1CO<br />
Figure 2a<br />
Dimensions<br />
Depth x width x height<br />
Note<br />
mm<br />
62 / 102 / 43<br />
Figure 2b<br />
Figure 2a: Positive-switching logic: Potential change-over<br />
switch to “+”, installation on output (11/14).<br />
Figure 2b: Negative-switching logic: Potential change-over<br />
switch to “-”, installation on output (11/14).<br />
Ordering data<br />
Type Qty. Order No.<br />
TIAL F10 1 1463540000<br />
Note<br />
Suitable for 12.8mm wide TERMSERIES base<br />
Accessories<br />
Note<br />
E.52 2021570000