Selection guide<br />

<strong>PLC</strong> ROCKWELL – CONTROL LOGIX<br />

Note<br />

DI<br />

DO<br />

AI<br />

AO<br />

<strong>PLC</strong> Cables Interfaces<br />

Input/Output cards St<strong>and</strong>ard Direct inputs/outputs Insulated inputs Insulated outputs<br />

- see page A.37 (H,R) or A.55 (A) - - see page A.61 - - see page A.65 -<br />

Manufacturer code Number/Type of channels Order No. Quantity Type Quantity Type Quantity Type Quantity<br />

1756-IA16 16 DI 7789031xxx 1 R2416 1<br />

1756-IA16I 16 DI 7789030xxx 1 R3632 1<br />

1756-IA8D 8 DI 7789048xxx 1 R1208 1<br />

1756-IB16 16 DI 7789039xxx 1 H2016 1 I2016 1<br />

1756-IB16D 16 DI 7789049xxx 1 H2016 1 I2016 1<br />

1756-IB16I 16 DI 7789049xxx 1 H2016 1 I2016 1<br />

1756-IB32 32 DI 7789041xxx 1 H2016 2 I2016 2<br />

1756-IC16 16 DI 7789031xxx 1 R2416 1<br />

1756-IH16I 16 DI 7789030xxx 1 R3632 1<br />

1756-IM16I 16 DI 7789030xxx 1 R3632 1<br />

1756-IN16 16 DI 7789031xxx 1 R3632 1<br />

1756-OA16 16 DO 7789056xxx 1 R3632 1<br />

1756-OA16I 16 DO 7789030xxx 1 R3632 1<br />

1756-OA8 8 DO 7789057xxx 1 R1208 1<br />

1756-OA8D 8 DO 7789048xxx 1 R1208 1<br />

1756-OA8E 8 DO 7789048xxx 1 R1208 1<br />

1756-OB16D 16 DO 7789040xxx 1 H2016 1 O2016 1<br />

1756-OB16E 16 DO 7789058xxx 1 H2016 1 O2016 1<br />

1756-OB16I 16 DO 7789059xxx 1 H2016 1 O2016 1<br />

1756-OB32 32 DO 7789042xxx 1 H2016 2 O2016 2<br />

1756-OB8 8 DO 7789151xxx 1 H2008 1 O2008 1<br />

1756-OB8EI 8 DO 7789152xxx 1 H2008 1 O2008 1<br />

1756-OC8 8 DO 7789153xxx 1 R2416 1<br />

1756-OH8I 8 DO 7789154xxx 1 R2416 1<br />

1756-ON8 8 DO 7789057xxx 1 R1208 1<br />

1756-OV16E 16 DO 7789058xxx 1 H2016 1 O2016 1<br />

1756-OW16I 16 DO 7789030xxx 1 R3632 1<br />

1756-OX8I 8 DO 7789155xxx 1 R2416 1<br />

1756-IF16 16 AI 7789032xxx 1 A3716 1<br />

1756-IF6I 6 AI, current applications 7789156xxx 1 A2508 1<br />

1756-IF6I 6 AI, voltage applications 7789157xxx 1 A2508 1<br />

1756-IF8 8 AI, current applications 7789035xxx 1 A2508 1<br />

1756-IF8 8 AI, voltage applications 7789036xxx 1 A2508 1<br />

1756-IR6I 6 AI 7789158xxx 1 A2508 1<br />

1756-OF4 4 AO, current applications 7789033xxx 1 A1504 1<br />

1756-OF4 4 AO, voltage applications 7789034xxx 1 A1504 1<br />

1756-OF6CI 6 AO, resistances 0 to 550 Ω 7789159xxx 1 A2508 1<br />

1756-OF6VI 6 AO 7789157xxx 1 A2508 1<br />

1756-OF8 8 AO, current applications 7789037xxx 1 A2508 1<br />

1756-OF8 8 AO, voltage applications 7789038xxx 1 A2508 1<br />

Universal solutions for <strong>PLC</strong> input/<br />

output cards<br />

A<br />

• Please, always take into account the characteristics of the <strong>PLC</strong> card (voltage, current…) when selecting <strong>interface</strong>s. In some cases, the card can work at<br />

higher voltages than those indicated in the <strong>interface</strong>.<br />

• The <strong>interface</strong>s are intended to be used inside an IP20 enclosure at least.<br />

• The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.<br />

* In the case that an input/output card does not appear in this table, you can check our on-line <strong>PLC</strong> selection guide at www.weidmueller.com where you will<br />