API Call Reference List of APIs<br />
OUTPUT Not Applicable<br />
RETURN<br />
GLOBAL STATUS frcBibDrvShow(int infoLvl )<br />
Note: The device address is 0xa8, where the BIB storage area resides.<br />
OK If the handle is attached.<br />
Error The routine returns ERROR in case of insufficient<br />
memory, if the device cannot be read, no BIB is found, or the BIB<br />
image is not valid.<br />
DESCRIPTION This show routine displays all attached BIB handles and the associated<br />
in<strong>for</strong>mation, such as the previous error code, whether a local<br />
memory pool is used, and the address of the BIB interface routines.<br />
If infoLvl is higher than 1 and an external show routine has<br />
been defined via the global function pointer frcBibShowRtn, the<br />
contents of the BIB itself is also displayed.<br />
INPUT An integer which indicates the infolvl required:<br />
0 describes in<strong>for</strong>mation about the handle<br />
1 describes in<strong>for</strong>mation about the interface routines and cache<br />
buffer<br />
2 describes the entire in<strong>for</strong>mation contained in the BIB<br />
OUTPUT The in<strong>for</strong>mation required.<br />
RETURN<br />
frcBibShowRtn<br />
OK If the handle is attached.<br />
Error The routine returns ERROR in case of insufficient<br />
memory, if the device cannot be read, no BIB is found, or the BIB<br />
image is not valid.<br />
When frcBibDrvShow( ) is called with an in<strong>for</strong>mation level<br />
VxWorks 5.5/Tornado <strong>2.2</strong> <strong>BSP</strong> <strong>Rel</strong>. <strong>1.0</strong> <strong>for</strong> <strong>PPMC</strong>-<strong>275</strong> 5 - 113