22.12.2012 Views

z/TPF Program Management - IBM

z/TPF Program Management - IBM

z/TPF Program Management - IBM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3. The JCL also references the format cards produced by the FACE table<br />

generator (fmta.mac, fmtb.mac, and so on). You will need to change the<br />

referenced HFS to the text mount HFS name where the format cards reside or<br />

you will need to move the format cards to a PDS and then reference that PDS.<br />

4. Submit the JCL for each of the online modules to be formatted.<br />

Create the general file loader input file<br />

Create a general file loader input file by entering bldtpf -ald controlfile, where<br />

controlfile is the path to tpf.cntl. See z/<strong>TPF</strong> and z/<strong>TPF</strong>DF System Generation for<br />

more information about creating a general file loader input file. See “ALDR input<br />

file” on page 158 for an example of a general file loader input file.<br />

Load system components to the loader general file<br />

Load fixed-file records<br />

74 z/<strong>TPF</strong> <strong>Program</strong> <strong>Management</strong><br />

Run the <strong>TPF</strong>LDR offline program with the ALDR parameter specified to load system<br />

components to the general file. You must load the following z/<strong>TPF</strong> components to<br />

the loader general file by using <strong>TPF</strong>LDR:<br />

v Core image restart (CIMR) area components.<br />

v CTKX.<br />

v IPLA.<br />

v IPLB.<br />

v <strong>Program</strong> attribute table (PAT).<br />

v Real-time components that are required in the loader general file and specified in<br />

the control file. See “Control files” on page 103 for more information about control<br />

files<br />

v Keypoints.<br />

Note: You must load all keypoints to the loader general file, but not necessarily<br />

to the online keypoint area. To avoid loading any particular keypoints to<br />

the online keypoint area, specify the keypoints on the @GFKEYPOINT<br />

control statement and do not specify them on the @KEYPOINT control<br />

statement.<br />

Sample JCL is provided in the base/samples/jcl directory.<br />

Complete the following steps to load fixed-file records:<br />

1. Create a pilot tape (symbolic name = SDF) with the system test compiler (STC)<br />

program. See z/<strong>TPF</strong> <strong>Program</strong> Development Support Reference for information<br />

about the system test compiler program.<br />

Note: A maximum of 2 147 483 647 records can be read or written from a pilot<br />

tape.<br />

2. Mount the pilot tape (SDF). This is the only input to the data loader.<br />

3. Enter the ZSLDR command to activate the data loader. See z/<strong>TPF</strong> Operations<br />

for more information about the ZSLDR command.<br />

Note: Once records are loaded to the z/<strong>TPF</strong> database, no utility is available to<br />

remove the records from the database. If it is necessary to delete<br />

previously loaded records from the z/<strong>TPF</strong> database, you must create and<br />

load a new pilot tape that contains dummy records. If the number of

Hooray! Your file is uploaded and ready to be published.