ecords decreases from one load to the next, the additional records from<br />
the first load will not be removed from the database.<br />
4. Take either of the following two actions:<br />
a. If the loaded records are meant for main storage, perform an online module<br />
IPL to place the records there.<br />
b. The system can be cycled to NORM state without an online module IPL. An<br />
IPL will be required in the future to place the records in main storage.<br />
Note:<br />
1. The data loader can be operated only while the z/<strong>TPF</strong> system is in 1052<br />
state unless the ID of the pilot tape is N. If the ID of the pilot tape is N,<br />
the z/<strong>TPF</strong> system can be in any state.<br />
2. In a loosely coupled facility, the subsystem cannot be above 1052 state<br />
in any processor unless the ID of the pilot tape is N. If the ID of the pilot<br />
tape is N, the subsystem can be in any state.<br />