Motor Description<br />

1.4 Order designation<br />

Additional data for options<br />

Option Short designation<br />

Terminal box arrangement (when viewing the DE)<br />

� On right side<br />

� On left side<br />

� Small terminal box and signal connector connection turned through 90��(cable<br />

entry from DE)<br />

� Small terminal box and signal connector connection turned through 90��(cable<br />

entry from NDE)<br />

� Small terminal box and signal connector connection turned through 180�<br />

Bearing version on DE<br />

� Single bearing for coupling or planetary gear units or low to moderate cantilever<br />

forces<br />

� Single bearing for increased speeds<br />

� Rotary shaft seal, oil–tight<br />

Vibration severity (acc. to IEC 34–14, DIN VDE 0530, Part 14)<br />

� Grade S with duplex bearing<br />

� Grade S with single bearing<br />

� Grade SR with single bearing<br />

1-20<br />

K09<br />

K10<br />

K83<br />

K84<br />

K85<br />

K00<br />

L37<br />

K18<br />

K05 1) 4)<br />

K02 1) 4)<br />

K03 1) 4)<br />

Shaft and flange accuracy (acc. to DIN 42955)<br />

� Tolerance R K04 2)<br />

DE shaft end<br />

� NDE shaft end (without keyway) K42<br />

Balancing<br />

� Half–key balancing L69<br />

Gearbox 5)<br />

� Motor prepared for mounting a ZF selector gearbox 2LG43 K00 3)<br />

Holding brake<br />

� Motor with mounted holding brake (DE) G46 4)<br />

Miscellaneous<br />

� 2nd rating plate, supplied loose<br />

� No encoder system<br />

K31<br />

H30<br />

1) Automatically includes version K04.<br />

2) Increased shaft accuracy<br />

3) For gearboxes 2LG42 (old version), use G97+K00; G97;<br />

G97 = non–standard cylindrical shaft end for SH 100, SE ∅ 28 x 60 mm<br />

4) Cannot be combined with gearbox mounting<br />

5) There must be a seal between motor flange and gearbox flange at SH 132 and SH160 due to the uninterrupted<br />

centering shoulder with sealing compound (e.g. Terostat 93, Teroson).<br />

© <strong>Siemens</strong> AG 2003 – 2006 All rights reserved<br />

<strong>AC</strong> <strong>Induction</strong> <strong>Motors</strong>, <strong>1PH4</strong> (APH4) – 04.06 Edition