Motor Description<br />
1.4 Order designation<br />
Additional data for options<br />
Option Short designation<br />
Terminal box arrangement (when viewing the DE)<br />
� On right side<br />
� On left side<br />
� Small terminal box and signal connector connection turned through 90��(cable<br />
entry from DE)<br />
� Small terminal box and signal connector connection turned through 90��(cable<br />
entry from NDE)<br />
� Small terminal box and signal connector connection turned through 180�<br />
Bearing version on DE<br />
� Single bearing for coupling or planetary gear units or low to moderate cantilever<br />
forces<br />
� Single bearing for increased speeds<br />
� Rotary shaft seal, oil–tight<br />
Vibration severity (acc. to IEC 34–14, DIN VDE 0530, Part 14)<br />
� Grade S with duplex bearing<br />
� Grade S with single bearing<br />
� Grade SR with single bearing<br />
1-20<br />
K09<br />
K10<br />
K83<br />
K84<br />
K85<br />
K00<br />
L37<br />
K18<br />
K05 1) 4)<br />
K02 1) 4)<br />
K03 1) 4)<br />
Shaft and flange accuracy (acc. to DIN 42955)<br />
� Tolerance R K04 2)<br />
DE shaft end<br />
� NDE shaft end (without keyway) K42<br />
Balancing<br />
� Half–key balancing L69<br />
Gearbox 5)<br />
� Motor prepared for mounting a ZF selector gearbox 2LG43 K00 3)<br />
Holding brake<br />
� Motor with mounted holding brake (DE) G46 4)<br />
Miscellaneous<br />
� 2nd rating plate, supplied loose<br />
� No encoder system<br />
K31<br />
H30<br />
1) Automatically includes version K04.<br />
2) Increased shaft accuracy<br />
3) For gearboxes 2LG42 (old version), use G97+K00; G97;<br />
G97 = non–standard cylindrical shaft end for SH 100, SE ∅ 28 x 60 mm<br />
4) Cannot be combined with gearbox mounting<br />
5) There must be a seal between motor flange and gearbox flange at SH 132 and SH160 due to the uninterrupted<br />
centering shoulder with sealing compound (e.g. Terostat 93, Teroson).<br />
© <strong>Siemens</strong> AG 2003 – 2006 All rights reserved<br />
<strong>AC</strong> <strong>Induction</strong> <strong>Motors</strong>, <strong>1PH4</strong> (APH4) – 04.06 Edition