Motor Components<br />
3.4 Gearboxes<br />
3.4.4 Electrical connection<br />
3-70<br />
Power supply for the selector unit: 24 V DC �10 %<br />
The mechanical selector unit requires a separate supply.<br />
2<br />
Fig. 3-6 Circuit diagram<br />
3<br />
4<br />
5 6<br />
M<br />
– S1 S2<br />
Connector (incl. in the scope of supply): Manufacturer, Harting; 7–pin + PE, type HAN 7D<br />
Table 3-8 Explanation of the connections<br />
Connector<br />
contact<br />
No.<br />
Number and<br />
designation<br />
In–<br />
put<br />
Out–<br />
put<br />
PE<br />
Voltage Current<br />
2 and 3 1 selector unit 0 – 24 V DC I max = 5 A<br />
(inrush current)<br />
4 and 6 2 limit<br />
switches<br />
0 0 24 V DC<br />
U max =42 V DC<br />
Table 3-9 Control sequence when selecting the gearbox stage<br />
I max = 5 A<br />
Gearbox stage selection Connector contact No.<br />
2 3 4/5<br />
(S1)<br />
When changing the ratio from stage i2 to i1 a Initial setting (f)<br />
b Selection sequence<br />
c Mechanical selection<br />
carried–out up to endstop 1)<br />
When changing the ratio from stage i1 to i2 d Initial setting (c)<br />
e Selection sequence<br />
f Mechanical selection<br />
carried–out up to endstop 1)<br />
L Contact closed 0 Contact open<br />
+24 V DC 0 V 0<br />
0<br />
L<br />
0 V +24 V DC L<br />
0<br />
0<br />
1) A limit switch (S1 or S2) sends a signal to the control after selection to switch out the selector unit.<br />
5/6<br />
(S2)<br />
© <strong>Siemens</strong> AG 2003 – 2006 All rights reserved<br />
<strong>AC</strong> <strong>Induction</strong> <strong>Motors</strong>, <strong>1PH4</strong> (APH4) – 04.06 Edition<br />
L<br />
0<br />
0<br />
0<br />
0<br />
L