Technical Data and Characteristics<br />

2.3 Axial and cantilever force diagram<br />

2.3.1 Cantilever force <strong>1PH4</strong>10�<br />

Permissible cantilever forces with duplex bearing (standard)<br />

Maximum continuous operating speed ns1max = 5600 rpm<br />

Mechanical limit speed nmax = 7500 rpm<br />

2-48<br />

F Q [N]<br />

5000<br />

4500<br />

4000<br />

3500<br />

3000<br />

2500<br />

1000<br />

n=1500 rpm<br />

n=2000 rpm<br />

n=3000 rpm<br />

n=4000 rpm<br />

n=5500 rpm<br />

n=6000 rpm 1)<br />

n=7500 rpm 1)<br />

Minimum cantilever force<br />

500<br />

0 10 20 30 40 50 60 70 80<br />

x [mm]<br />

Fig. 2-11 Permissible cantilever force FQ at a distance x from the shaft shoulder for a<br />

nominal bearing lifetime of 20 000 h.<br />

1) Permissible for continuous operation, however with shorter bearing lifetime<br />

© <strong>Siemens</strong> AG 2003 – 2006 All rights reserved<br />

<strong>AC</strong> <strong>Induction</strong> <strong>Motors</strong>, <strong>1PH4</strong> (APH4) – 04.06 Edition