3.4.5 Gearbox stage selection<br />
© <strong>Siemens</strong> AG 2003 – 2006 All rights reserved<br />
<strong>AC</strong> <strong>Induction</strong> <strong>Motors</strong>, <strong>1PH4</strong> (APH4) – 04.06 Edition<br />
Motor Components<br />
3.4 Gearboxes<br />
When changing the gearbox stage, the following information must be carefully observed:<br />
� Only change over the gearbox stage at standstill; e.g. while changing the tool.<br />
� During selection, the direction of rotation should be changed approximately 5<br />
times per second. The gears normally mesh at the first direction of rotation<br />
change so that selection times of between 300 and 400 ms can be achieved.<br />
The ”oscillation” function is provided in the SIMODRIVE 611 analog drive converter<br />
for this purpose.<br />
� The gearbox stage should not be changed without oscillation.<br />
� The motor may only start to accelerate 200 ms after the changeover has been<br />
completed.<br />
� The selection must be monitored using a time relay. After 2 s, the selection<br />
must be reversed, if the selection command was not able to be executed.<br />
A time limit of 10 s should be provided for approx. 4 to 5 additional selection<br />
operations.<br />
Initiate a gearbox stage change<br />
Brake the <strong>AC</strong> motor from the operating speed down to zero speed.<br />
Maintain the controller enable at the transistor PWM converter.<br />
Initiate the ”oscillation” function (select terminal)<br />
Selector unit for the gearbox stage change ON Selector unit back to the initial setting<br />
No<br />
Has the gearbox<br />
stage change been completed<br />
within 2 s? (feedback signal from limit<br />
switch S1 or S2 from the gearbox<br />
selector unit)<br />
Yes<br />
Cancel the ”oscillation” function<br />
Repeat<br />
gearbox<br />
stage<br />
change.<br />
No<br />
Yes<br />
Gearbox stage change was not<br />
successful, shutdown the <strong>AC</strong> motor.<br />
Selector unit OFF after 200 ms Check the system<br />
Gearbox stage change completed<br />
Fig. 3-7 Function sequence when changing the gearbox stage<br />
4 to 5<br />
gearbox stage change<br />
attempts executed?<br />
(duration, approx. 10 s)<br />
3-71