3.4.5 Gearbox stage selection<br />

© <strong>Siemens</strong> AG 2003 – 2006 All rights reserved<br />

<strong>AC</strong> <strong>Induction</strong> <strong>Motors</strong>, <strong>1PH4</strong> (APH4) – 04.06 Edition<br />

Motor Components<br />

3.4 Gearboxes<br />

When changing the gearbox stage, the following information must be carefully observed:<br />

� Only change over the gearbox stage at standstill; e.g. while changing the tool.<br />

� During selection, the direction of rotation should be changed approximately 5<br />

times per second. The gears normally mesh at the first direction of rotation<br />

change so that selection times of between 300 and 400 ms can be achieved.<br />

The ”oscillation” function is provided in the SIMODRIVE 611 analog drive converter<br />

for this purpose.<br />

� The gearbox stage should not be changed without oscillation.<br />

� The motor may only start to accelerate 200 ms after the changeover has been<br />

completed.<br />

� The selection must be monitored using a time relay. After 2 s, the selection<br />

must be reversed, if the selection command was not able to be executed.<br />

A time limit of 10 s should be provided for approx. 4 to 5 additional selection<br />

operations.<br />

Initiate a gearbox stage change<br />

Brake the <strong>AC</strong> motor from the operating speed down to zero speed.<br />

Maintain the controller enable at the transistor PWM converter.<br />

Initiate the ”oscillation” function (select terminal)<br />

Selector unit for the gearbox stage change ON Selector unit back to the initial setting<br />

No<br />

Has the gearbox<br />

stage change been completed<br />

within 2 s? (feedback signal from limit<br />

switch S1 or S2 from the gearbox<br />

selector unit)<br />

Yes<br />

Cancel the ”oscillation” function<br />

Repeat<br />

gearbox<br />

stage<br />

change.<br />

No<br />

Yes<br />

Gearbox stage change was not<br />

successful, shutdown the <strong>AC</strong> motor.<br />

Selector unit OFF after 200 ms Check the system<br />

Gearbox stage change completed<br />

Fig. 3-7 Function sequence when changing the gearbox stage<br />

4 to 5<br />

gearbox stage change<br />

attempts executed?<br />

(duration, approx. 10 s)<br />

3-71