Motor Components<br />

3.1 Thermal motor protection<br />

!<br />

3-58<br />

Warning<br />

The integrated temperature sensor protects the motors against overload<br />

conditions up to 4 � I0 60K and speed 0.<br />

Sufficient protection is no longer provided for thermally critical load situations, e.g.<br />

for a high overload condition at motor standstill. In this case, other protective<br />

measures must be provided, e.g. a thermal overcurrent relay.<br />

If they exist, reduced data for standstill are specified.<br />

R [kΩ]<br />

3<br />

2<br />

1<br />

0<br />

0<br />

100<br />

I D = 2 mA<br />

200 300<br />

� U [°C]<br />

Fig. 3-1 Resistance characteristic as a function of the KTY 84 thermistor temperature<br />

© <strong>Siemens</strong> AG 2003 – 2006 All rights reserved<br />

<strong>AC</strong> <strong>Induction</strong> <strong>Motors</strong>, <strong>1PH4</strong> (APH4) – 04.06 Edition