Motor Description<br />

1.7 Bearing design<br />

Grease change interval<br />

0.8 � tLW<br />

1-26<br />

( tLW = bearing change interval)<br />

Continuous operating speed<br />

The max. permissible continuous operating speed nS1cont depends on the bearings<br />

and the shaft height.<br />

Table 1-9 Assignment, max. speed/continuous operating speed to shaft height and bearing design<br />

SH<br />

[mm]<br />

Duplex bearing<br />

[rpm]<br />

Single bearing<br />

[rpm]<br />

Bearing for increased<br />

speed<br />

[rpm]<br />

n max 1) n s1cont n max 1) n s1cont n max 1) n s1cont<br />

100 7500 5600 9000 6500 12000 10000<br />

132 6700 5200 8000 6000 10000 9250<br />

160 5300 4000 6500 4500 8000 7000<br />

Important<br />

If the motor is operated at speeds between ns1cont and nmax, a speed duty cycle<br />

with low speeds and standstill intervals is required in order to reliably guarantee<br />

that the grease is well–distributed in the bearings.<br />

1) Mechanical limiting speed (permissible for 10 min. cycle with: 3 min n max, 6 min 2/3 n max, 1 min<br />

standstill)<br />

© <strong>Siemens</strong> AG 2003 – 2006 All rights reserved<br />