Performance Data Evaluating Performance<br />

What do lamp isofootcandle diagrams tell us, and<br />

how should they be used?<br />

Overview<br />

Isofootcandle Diagrams Versus Point-by-Point Calculations<br />

An isofootcandle curve is a line plotted in an imaginary plane, perpendicular to<br />

the axis of the light source (typically horizontal and/or vertical) and comprised of<br />

points of equal illuminance. See diagram 1.<br />

This curve can be used to illustrate the maximum distance from the source the<br />

desired illuminance can be achieved and the region through which this level is<br />

met or exceeded. A series of isofootcandle curves for a given light source is<br />

known as an isofootcandle diagram. See diagram 2.<br />

Each isofootcandle curve represents a unique illuminance value in the same imaginary<br />

plane.<br />

What is the most accurate way to evaluate emergency<br />

lighting units to determine maximum center-to-center<br />

spacing?<br />

Lamp isofootcandle diagrams are commonly used to compare one light source to<br />

another in terms of light distribution and intensity. For this reason, many lamp<br />

manufacturers provide isocontour diagrams for the lighting professional.<br />

However, lamp isofootcandle diagrams alone in no way offer a reasonable prediction<br />

of the illuminance levels one might expect to obtain for a horizontal work<br />

plane or path of egress.<br />

The diagrams are simplistic and do not take into account any of the application<br />

variables known to impact an indoor lighting layout including, but not limited to:<br />

the surface reflectance of the ceiling, walls and floors; the room geometry; and<br />

the true distance and angle at which the light strikes the path of egress and other<br />

surfaces. Collectively, these variables have a major impact on the overall lighting<br />

layout.<br />

344 Emergency / PSG8 www.lithonia.com<br />

6<br />

4<br />

2<br />

0<br />

2<br />

4<br />

6<br />

Ft.<br />

6<br />

4<br />

2<br />

0<br />

2<br />

4<br />

6<br />

6<br />

4<br />

2<br />

0<br />

2<br />

4<br />

6<br />

Ft.<br />

6<br />

4<br />

2<br />

0<br />

2<br />

4<br />

6<br />

HORIZONTAL<br />

VERTICAL<br />

LTL10586<br />

MR24 K0606<br />

6-volts,5.4-wattskrypton<br />

HORIZONTAL<br />

VERTICAL<br />

Diagram 1<br />

Isofootcandle curve<br />

10 20 Ft.<br />

1 0.5 0.3<br />

1 0.5 0.3<br />

10 20 Ft.<br />

Diagram 2