26.12.2012 Views

Sections

Sections

Sections

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fixture/Ordering Compatability Example: THC 400M A15 120 KW1S<br />

Series<br />

TE<br />

THC<br />

THS<br />

THP<br />

THR<br />

THV<br />

TXS<br />

TXP<br />

TXC<br />

TXL<br />

TXR<br />

TXV<br />

TXS<br />

SH<br />

SX<br />

SPG<br />

Sensor Operation<br />

Intended Use<br />

The KiloWatch ® II Integral Sensor System<br />

is designed for maximum control. Each<br />

unit contains an integral sensor that<br />

mounts directly to the reflector. Application<br />

opportunities include warehouses or<br />

select storage areas within manufacturing<br />

facilities.<br />

Features<br />

SYSTEM<br />

Solid state relay<br />

Dual level or 2 separate capacitors<br />

SCWA or CWA ballast only<br />

Passive infrared sensor with Fresnel<br />

Lens<br />

Adjustable time delay .5 to 20 minutes<br />

15 minute start up timer.<br />

Green LED Activity Indicator<br />

SENSOR<br />

Up to 45-foot mounting height<br />

Mounts to reflector via adjustable<br />

bracket<br />

Bi-Level Lighting with Integral Sensor System<br />

• 360° coverage within the luminaire’s<br />

lighting distribution<br />

Size: circular, 3.9” dia., 1.34” deep<br />

Color: white<br />

Relative humidity: 20% to 90% non-condensing<br />

Operating temperature: 14°F to 131°F,<br />

(-10°C to 55°C)<br />

LT option operating temperature:<br />

-40°F to 131°F, (-40°C to 55°C)<br />

Listings - UL Listed to U.S. and Canadian<br />

safety standards.<br />

KiloWatch Option Designations:<br />

KW1S – Luminaire supplied with 120V AC<br />

control components. AC sensor controlled<br />

systems (120/208/240/347/480V). Reduces<br />

wattage by 50%.<br />

KW150S – Luminaire supplied with 120V<br />

AC control components. AC sensor controlled<br />

systems (120/208/240/347/480V).<br />

Reduces light output by 50%.<br />

Optical Voltage<br />

150S<br />

E17 A125 120 KW1S CRT DCY<br />

250S<br />

E22 A165 208<br />

TEF DHX<br />

400S<br />

A15 PA16 240<br />

TR DSQ<br />

1000S<br />

A16 PA22 277<br />

SCWA FWG<br />

100MP<br />

A17 PA22C 347<br />

RC3NP GFWG<br />

175MP<br />

A22 PA22SP 480<br />

LCPP HC3P<br />

175M<br />

A14 PA25ALE<br />

LC3P HKF<br />

200M<br />

A26 PA25D<br />

HC3P HKM<br />

200MP<br />

A30 PA22GLE<br />

HOCS HKMG<br />

250M<br />

A23 PA22N<br />

HOCU LC3P<br />

250MP<br />

A20<br />

LOCS LGG<br />

300M<br />

300MP<br />

320M<br />

NOTES:<br />

LOCU<br />

CF<br />

LPF<br />

1 50% power.<br />

2 50% lumen.<br />

1<br />

KW150S2 KW1S LT1 KW150 LT2 Wattage/lamp Options<br />

320MP<br />

350M<br />

350MP<br />

400M<br />

400MP<br />

SF<br />

450M<br />

DF<br />

450MP<br />

QRS<br />

1000M<br />

QRSTD<br />

1000MP<br />

EC<br />

GL<br />

TOB<br />

T73<br />

CR<br />

For option compatibility,<br />

See pages 395 and 397.<br />

Accessories<br />

LPM<br />

LPMG<br />

PPH<br />

TPH<br />

SCK<br />

SCK48<br />

SCK108<br />

SMB18<br />

SMB24<br />

TMB30<br />

TMB48<br />

WG<br />

WGG<br />

The control is accomplished through an integral passive infrared sensor mounted to the reflector. Upon<br />

initial power-up, a timer brings the lamp to full operating temperature for a preset 15-minute period.<br />

Once the unit is warmed up, the sensor switches the unit to the low mode, then relies on heat changes<br />

caused by body movement or moving equipment within the sensor coverage to switch the unit to full<br />

lumen output from a pre-selected level (50% power or 50% lumen).<br />

The high level delay controls the time that the fixture remains in the high mode after motion is no longer<br />

sensed. This adjustment is factory set at approximately 75 seconds (minimum), but may be adjusted if<br />

required. The available range is 75 seconds to approximately 30 minutes.<br />

www.lithonia.com<br />

keyword: KW<br />

HID Control System<br />

KiloWatch ®<br />

II<br />

Description<br />

KW1S KiloWatch integral sensor unit<br />

(50% power)<br />

KW150S KiloWatch integral sensor unit<br />

(50% lumen)<br />

KW1S LT KiloWatch intergal sensor unit<br />

(50% power), Low temperature<br />

KW150S LT KiloWatch integral sensor unit<br />

(50% lumen), Low temperature<br />

SENSOR COVERAGE CHART<br />

Indoor HID / PSG8<br />

NEW<br />

387

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!