<strong>Satchwell</strong> Controllers & Sensors<br />
CSC Controller<br />
Time<br />
Spec. no. control Output<br />
Time<br />
Spec. no. control Output<br />
DR DRT DWT DWT DST DOT DOS RPW<br />
3253 3453 0001 0002 0001 0002 0001 4425<br />
Adjustable scale none none none none none none none exp.<br />
Location room room imm. imm. clamp outs. outs. room<br />
Optimisers<br />
SVT 4201 Analogue 230V ● (included)<br />
on/off<br />
DRT DRT DWT DWT DST DOT<br />
3451 3453 0001 0002 0001 0002<br />
Adjustable scale exp. none none none none none<br />
Location room room imm. imm. clamp outs.<br />
Compensators<br />
CSC 5252 None 230V or ● ● ● ● ● ●<br />
24Vac<br />
CSC 5352 Digital ● ● ● ● ● ●<br />
Data sheet DS 2.021<br />
Product Selection - page no. 21 21 24 24 24 25<br />
SVT Controllers<br />
SVT 4251 Digital ● (included)<br />
Product Selection - page no. 21 21 24 24 24 25 25 25<br />
CXT, CZT, CXR Controllers<br />
Spec. no. Control Output<br />
DRT DRT DRT DDT DWT DWT DST RPW<br />
3451 3453 3651 0001 0001 0002 0001 4425<br />
Adjustable scale exp. none exp. none none none none exp.<br />
Location room room room duct imm. imm. clamp room<br />
Climatronic<br />
CXT 56<strong>05</strong> –10...120°C 24V ● ● ● ●<br />
modulating<br />
CZT 53<strong>05</strong> –10...120°C 0...10Vdc ● ● ● ● ● ● ●<br />
CXR 58<strong>05</strong> –10...120°C 24V<br />
modulating<br />
● ● ● ● ● ● ●<br />
Data sheet DS 2.101, 2.1<strong>05</strong>, 2.110<br />
Product Selection - page no. 21 21 21 23 24 24 24 25<br />
KMC Controller<br />
Spec. no. Control Output<br />
DRT DRT DDT DWT DST DOT DRTH DDTH RPW<br />
3453 3451 0001 0001 0001 0002 4425<br />
Adjustable scale none exp. none none none none none none exp.<br />
Location room room duct imm. clamp outs. room duct room<br />
Keyboard<br />
KMC 3201 –40...150°C 0...10Vdc ● ● ● ● ● ● ● ● ●<br />
or<br />
0...100% rh<br />
Data sheet DS 2.101, 2.1<strong>05</strong>, 2.110<br />
Product Selection - page no. 21 21 23 24 24 25 22 23 25<br />
URC, BRC Controller<br />
Spec. no.<br />
DU DUS MN-S DDU DDT<br />
1-5 0001 0001<br />
Adjustable scale none exp. note1 none none<br />
Location room room room duct duct<br />
UniFact Pro<br />
URC-41 ● ● ● ● ●<br />
URC-51 ● ● ● ● ●<br />
Bonsai<br />
BRC-41 (Pro) ● ● ● ● ●<br />
BRC-51 (Lite) ● ● ● ● ●<br />
Data sheet DS 10.130 & 4.103<br />
Product Selection - page no. 22 22 14 23 23<br />
Note 1: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable<br />
PRODUCT COMPATIBILITY<br />
35<br />
MMC Controllers<br />
Spec. no. Control Output<br />
DRT DRT DU MN-S DWT DST DDU DOT, DOW RPW DRH DDH<br />
3453 3651/2 DUS 1-5 0001/2 0001 0001 DOS 2701 4425 DRTH DDTH<br />
Adjustable scale none yes note1 note2 none none none none none exp. none none<br />
Location room room room room imm. clamp duct outs. outs. room room duct<br />
Spec. no.<br />
DRT DRT DDT DWT DST DOT, DOW RPW<br />
3453 3651 0001 0001 0001 DOS 2701 4425<br />
Adjustable scale none exp. none none none none none exp.<br />
Location room room duct imm. clamp outs. outs. room<br />
District Heating Controller<br />
MMC 4601 –40...150°C 0...10Vdc ● ● ● ● ●<br />
Micro Management Controller with built-in time schedules<br />
MMC 4701 –40...150°C Pulsed<br />
24V or<br />
0...10Vdc<br />
● ● ● ● ● ● ● ●<br />
Data sheet DS 2.751, 2.701<br />
Product Selection - page no. 21 21 23 24 24 25 25 25<br />
Spec. no. Control Output<br />
DRTH DDTH RPW<br />
4425<br />
Adjustable scale none none exp.<br />
Location room duct room<br />
Micro Management Controller with built-in time schedules<br />
MMC 4701 20...90%rh Pulsed<br />
24V or<br />
0...10Vdc<br />
● ● ●<br />
Data sheet DS 2.701<br />
Product Selection - page no. 22 23 25<br />
CZU Controller<br />
Spec. no. Control Output<br />
DRT DRT DRT DRT DDT DDU DDU<br />
3451 3453 3801 3851 0001 0001 1803<br />
Adjustable scale exp. none exp. exp. none none none<br />
Location room room room room duct duct duct<br />
Zonemaster<br />
CZU 4201 10...40°C 24V ● ● ● ● ● ● ●<br />
Data sheet DS 2.201<br />
Product Selection - page no. 21 21 22 22 23 23 23<br />
MN Controllers (LONMARK ® )<br />
DRT DRT DU MN-S DWT DST DDU DOT DOW DRH DDH<br />
3453 3651/2 4301 1-5 0001/2 0001 0001 DOS 2701 DRTH DDTH<br />
Adjustable scale none yes none note1 none none none none none none none<br />
Location room room room room imm. clamp duct outs. outs. room duct<br />
Spec. no.<br />
MN 11/13 ●<br />
MN 50 ● ● ● ● ● ● ● ● ● ● ●<br />
MN 100 ● ● ● ● ● ● ● ● ● ● ●<br />
MN 150 ● ● ● ● ● ● ● ● ● ● ●<br />
MN 200 ● ● ● ● ● ● ● ● ● ● ●<br />
MN VAV ●<br />
Product Selection<br />
- page no. 21 21 22 14 24 24 23 25 25 22 23<br />
Note 1: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable<br />
MN Controllers (Bus-du-jour ® )<br />
MN 300 ● ● ● ● ● ● ● ● ● ● ● ●<br />
MN 440 ● ● ● ● ● ● ● ● ● ● ●<br />
MN 500 ● ● ● ● ● ● ● ● ● ● ●<br />
MN 620 ● ● ● ● ● ● ● ● ● ● ●<br />
Product Selection<br />
- page no. 21 21 22 14 24 24 23 25 25 25 22 23<br />
Note 1: DU 4301 is non adjustable, DUS 4302 and DUSF 4351/4352 are adjustable<br />
Note 2: MN-S1 is not adjustable, MN-S2/3/4/5 are adjustable