<strong>Satchwell</strong> Controllers<br />

Humidity & Temperature Controllers<br />

Item Spec. no. Current Equipment Notes Remarks<br />

Duotronic EC EC1-2 to<br />

EC26-2<br />

Duotronic E 576-2-201 to<br />

576-2-458<br />

Duotronic 565<br />

SET 565-1-404 to<br />

565-1-455<br />

SEH 565-1-501<br />

SETH 565-1-601 to<br />

565-1-610<br />

Humidity Controllers<br />

Item Spec. no. Range Current Equipment Notes Remarks<br />

Monotronic ZH 574-2-701 45...65% rh ● ● Detectors/<br />

sensors to<br />

Climatronic CZH 562-3-501 30...55% rh ● ●<br />

be changed<br />

562-3-502 45...70% rh ● ●<br />

Keyboard KZH 4551 20...80% rh ● ●<br />

MMC 2401 20...90% rh ●<br />

MMC 2402 20...90% rh ●<br />

MMC 2403 20...90% rh ●<br />

MMC 2451 20...90% rh ●<br />

MMC 2452 20...90% rh ●<br />

MMC 2453 20...90% rh ●<br />

MMC 3701 20...90% rh ●<br />

Product Selection - page no. 18 19<br />

Step Controllers<br />

KMC 3201<br />

MMC 4701<br />

Item Spec. No. of Switch Current Equipment Notes Remarks<br />

no. steps rating<br />

IAC 420<br />

IAC 600<br />

FLS 1502<br />

MC and MD MC 1201 6 6 Amp ●<br />

MC 1202 9 6 Amp ●<br />

MC 1203 12 6 Amp ●<br />

MD 3201 5 20 Amp ●<br />

MD 3226 10 20 Amp ●<br />

TSU 569-2-402 2 5 Amp ●<br />

FBS 583-1-551 6 Binary ● ●<br />

Product Selection - page no. 20 21 18<br />

Zonemaster & Temperature Controllers<br />

Item Spec. no. Control Output Current Equipment Notes Remarks<br />

CZU 4201<br />

IAC 420<br />

Zonemaster 569-1-201 10...40°C 24V ●<br />

CZU 569-2-201 10...40°C 24V ●<br />

569-3-201 10...40°C 24V ●<br />

569-1-202 10...40°C 24V ●<br />

569-2-202 10...40°C 24V ●<br />

569-3-202 10...40°C 24V ●<br />

569-1-203 10...40°C 24V ●<br />

569-2-203 10...40°C 24V ●<br />

569-3-203 10...40°C 24V ●<br />

NSU 569-1-401 0...10V dc ●<br />

569-2-401 to reset CZU ●<br />

CZP 569-1-501 0...250mm 0.5 + ●<br />

569-2-501 H2O 10Vdc<br />

CZV 569-2-501 0.4...10 0...10Vdc ● 10Vdc and<br />

m/s 15Vdc fixed<br />

No single direct replacement<br />

for these controls however a<br />

combination of keyboard or<br />

climatronic may be suitable.<br />

Refer to <strong>Satchwell</strong> with full<br />

specification of obsolete<br />

control and temperature<br />

range controller or contact<br />

your local sales engineer.<br />

If KMC/MMC is<br />

supplied then<br />

actuators to be<br />

changed to 0...10V<br />

signal<br />

KZH and KMC<br />

terminals are<br />

different<br />

There is no direct<br />

replacement. However,<br />

if the controls are<br />

being replaced and<br />

they are installed<br />

within a panel then the<br />

FLS may be considered.<br />

Note: The FLS requires<br />

a 0...10 volt dc control<br />

signal.<br />

The IACs need to be<br />

engineered<br />

TSU 569-2-402 ● Use relays to cover<br />

the 5A rating<br />

Product Selection - page no. 19 20<br />

OBSOLETE PRODUCTS<br />

The CZU 4201 must be<br />

installed adjacent to<br />

the fan coil unit with a<br />

DRT 3451 if temp<br />

adjustment from the<br />

room is required.<br />

37<br />

Compensator Controllers<br />

Item Spec. no. Current Equipment Notes Remarks<br />

CSC 5252<br />

CSC 5352<br />

Compensators<br />

CXC 562-3-701 ● ● Alternatively use MMC 4701<br />

and associated detectors/sensors.<br />

562-3-702 ● Mark 5 CSC's can use<br />

562-3-706 ● existing sensors.<br />

562-3-711 ●<br />

COC 562-3-704 ●<br />

562-3-707 ●<br />

562-3-710 ●<br />

CXOC 562-3-713 ●<br />

562-3-715 ●<br />

CD 567-1-201 ● Actuator to be replaced<br />

567-2-201 ● with XRM 3201.<br />

CSC 561-2-701 ●<br />

561-2-702 ●<br />

561-2-703 ●<br />

561-2-726 ●<br />

561-2-727 ●<br />

561-2-776 ●<br />

561-2-777 ●<br />

Response RR No equivalent available<br />

Regulator XC10<br />

Calibrator Box<br />

CC C4 ● ●<br />

C4X ● ●<br />

C5 ● ●<br />

C5X ●<br />

Compensators<br />

C6 572-1-276 No direct replacement<br />

572-1-376<br />

C7 573-1-201 ● ●<br />

573-1-251 ● ●<br />

573-1-276 ●<br />

SXC 565-1-217<br />

565-1-218<br />

565-1-219<br />

565-1-220<br />

565-1-223<br />

565-1-224<br />

No direct replacement<br />

565-1-221 ●<br />

565-1-222 ●<br />

565-1-225 ●<br />

CSC CSC 4201 ●<br />

CSC 4301 ●<br />

CSC 4202 ●<br />

CSC 4302 ●<br />

CMC CMC 3803 No direct replacement<br />

CSMC CSMC 3804<br />

CSMC 38<strong>05</strong><br />

No direct replacement<br />

Product Selection - page no. 17 17<br />

Optimiser Controllers<br />

If original actuator is to<br />

be used and it is a K or P<br />

series then a transformer<br />

must be supplied with<br />

CSC compensator.<br />

If original actuator is<br />

ALXS then a<br />

separate transformer<br />

is required.<br />

Used with the C4X<br />

and C5X system.<br />

Change complete<br />

system to CSC.<br />

* If original actuator is to<br />

be used and it is a K or P<br />

series than a transformer<br />

must be supplied with the<br />

compensator.<br />

Use MMC and<br />

associated<br />

detectors/sensors.<br />

See above remark*.<br />

Replace C7W and C7P<br />

detectors/sensors.<br />

Refer to Customer Care<br />

Centre or your local<br />

sales engineer.<br />

See above remark*.<br />

Replace<br />

detectors/sensors.<br />

Item Spec. no. Current Equipment Notes Remarks<br />

SVT 4201<br />

SVT 4251<br />

Optimisers<br />

SST 1801 565-1-801 ● ●<br />

SST 1802 565-1-802 No direct replacement<br />

SST 1803 565-1-803<br />

SST 1804 565-1-804<br />

SST 18<strong>05</strong> 565-1-8<strong>05</strong> ● ●<br />

SST 1806 565-1-806 No direct replacement<br />

SST 1871 565-1-871<br />

ESS 2202 588-2-202 ● ●<br />

SMT 1201 587-1-201 No direct replacement<br />

Optimiser/Compensators<br />

CMC 1801 561-1-801 No direct replacement<br />

CMC 1803 561-1-803<br />

CMC 1826 561-1-826<br />

CMC 3803 561-3-803<br />

CSMC 3804 561-3-804<br />

CSMC 38<strong>05</strong> 561-3-8<strong>05</strong><br />

Product Selection - page no. 17 17<br />

The detector/sensor<br />

is supplied with the<br />

SVT but it has no<br />

outside detector.<br />

Refer to Customer<br />

Care Centre or your<br />

local sales engineer.