12.01.2013 Views

NNR IN RAPIDLY ROTATED METALS By - Nottingham eTheses ...

NNR IN RAPIDLY ROTATED METALS By - Nottingham eTheses ...

NNR IN RAPIDLY ROTATED METALS By - Nottingham eTheses ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

- 89 -<br />

identical to those of the rotor sample chamber. All measurements<br />

were recorded at room temperature (295 K) in a magnetic field of<br />

1.35 T. With the PSD in quadrature phase at high gain, resonance<br />

frequencies could be determined precisely from the detected signal<br />

by fine adjustment of the dial settings on the frequency synthesiser.<br />

In obtaining each Knight shift value a series of comparisons<br />

of the resonance frequencies of the metal and reference material<br />

were made. After a small correction of up to 10 Hz to account<br />

for a very slight difference in the magnetic fields at the rotor<br />

and the reference sample (see Section 5.5) the Knight shifts were<br />

calculated from the equation (m<br />

- vr)/vr' Several separate deter-<br />

minations were made, changing the samples used and also varying<br />

slightly the rotation rate and the magnetic field. From eight<br />

different series of measurements the mean value of the aluminium<br />

Knight shift was 1640.0 ppm and the extreme values were 1638.9 and<br />

1640.7 ppm. The estimated possible error in the measured resonance<br />

frequency of each sample was ±5 Hz. Similar errors in determin-<br />

ing the magnitude of the applied correction lead to an overall esti-<br />

mate of the total possible error in each determination of (v - Vr)<br />

of ±20 Hz. Hence with yr equal to 15 MHz the maximum possible<br />

error in any single Knight shift estimate was approximately ±1.3 ppm.<br />

Three specimens of aluminium powder were used in the measure-<br />

ments: (a), (b) and (d). Powders prepared from the two grades of<br />

aluminium wire ((a) and (b)) were sieved so that the maximum part-<br />

icle size was limited to 44 pm. Originally the powder specimens<br />

were encapsulated in epoxy resin in the manner described in Section<br />

5.9. This was later found to be unnecessary so the powders were<br />

packed directly into the rotor sample chambers which were then sealed

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!