25.01.2013 Views

Hydro-Mechanical Properties of an Unsaturated Frictional Material

Hydro-Mechanical Properties of an Unsaturated Frictional Material

Hydro-Mechanical Properties of an Unsaturated Frictional Material

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

84 CHAPTER 4. EXPERIMENTAL SETUPS<br />

between the bottom plate <strong>an</strong>d the plexiglas tube prevent from leakage. A tube with a valve is<br />

connected to the water reservoir below the ceramic disk. By using a cylinder attached to this<br />

tube the water outflow is measured. At all 6 openings (3 openings for tensiometer sensors, 3<br />

openings for TDR sensors) enable to equip the specimen with tensiometer sensors as well as<br />

TDR sensors. In 3 depths along the column 2 openings are installed opposite to each other.<br />

The openings are installed equally spaced (see Fig. 4.9). In three layers with a dist<strong>an</strong>ce <strong>of</strong><br />

60 mm pairs <strong>of</strong> tensiometer <strong>an</strong>d TDR sensors are placed to measure simult<strong>an</strong>eously pore-<br />

water pressure <strong>an</strong>d volumetric water content in the specimen during the experiment. The<br />

same tensiometer sensors <strong>an</strong>d TDR sensors used for column testing device I were used for<br />

column testing device II.<br />

4.5 UPC Controlled-Suction Oedometer Cell<br />

One dimensional compression <strong>an</strong>d rebound tests <strong>an</strong>d collapse tests were performed by using<br />

the controlled-suction oedometer cell (Fig. 4.10). Similar to the modified pressure plate<br />

apparatus the cell allows to apply suction to the specimen <strong>an</strong>d to keep the suction const<strong>an</strong>t<br />

during the testing procedure.<br />

The controlled-suction oedometer cell is also equipped with a burette <strong>an</strong>d a scale with the<br />

same accuracy as the equipment for the modified pressure plate apparatus, one air-pressure<br />

system for application <strong>of</strong> matric suction as well as one air-pressure system for application <strong>of</strong><br />

vertical net stress. The application <strong>of</strong> matric suction to the specimen is equal to the procedure<br />

used in the modified pressure plate apparatus (i.e. h<strong>an</strong>ging water column technique, axis<br />

σ*<br />

σ*<br />

- Air pressure system - ua Air pressure Burette - uw Scale Dial gagesystem<br />

- Supply<br />

Figure 4.10: Controlled-suction oedometer cell<br />

Supply - ua Supply - uw<br />

cell oedometer Controlled-suction

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!