11.2. TESTING DEVICES AND EQUIPMENT 207<br />

+ The procedure is not time consuming.<br />

+ Volumetric water content measurements θ(t) <strong>an</strong>d suctions measurements ψ(t) c<strong>an</strong> be<br />

used to directly determine hydraulic functions (suction-water content relation, unsatu-<br />

rated hydraulic conductivity).<br />

- Expensive equipment is required (i.e., TDR sensors, tensiometers, 2 computers for com-<br />

puting results).<br />

- Careful calibration <strong>of</strong> the sensors is necessary.<br />

- Preparation <strong>of</strong> the specimen is time consuming <strong>an</strong>d a large mass <strong>of</strong> material to be tested<br />

is needed.<br />

- The specimen must be a disturbed specimen.<br />

Following adv<strong>an</strong>tages <strong>an</strong>d disadv<strong>an</strong>tages were found when using the S<strong>an</strong>d Column Testing<br />

Device II :<br />

+ Drainage tr<strong>an</strong>sient state tests c<strong>an</strong> be performed under various flow rates. The influence<br />

<strong>of</strong> flow rate on the hydraulic behavior <strong>of</strong> unsaturated s<strong>an</strong>d c<strong>an</strong> be determined using the<br />

attached air-pressure system.<br />

+ Measurements <strong>of</strong> ch<strong>an</strong>ges in volume c<strong>an</strong> be performed.<br />

+ The procedure is not time consuming.<br />

+ Volumetric water content measurements θ(t) <strong>an</strong>d suctions measurements ψ(t) c<strong>an</strong> be<br />

used to directly determine hydraulic functions.<br />

- Expensive equipment is required (i.e., TDR sensors, tensiometers, 2 computers for com-<br />

puting results).<br />

- Careful calibration <strong>of</strong> the sensors is necessary.<br />

- It is not useful to carry out steady state tests in the s<strong>an</strong>d column testing device II, due<br />

to the size <strong>of</strong> specimen. The testing procedure would be very time consuming.<br />

- The specimen is a disturbed specimen.<br />

Even it is a time consuming procedure for prediction <strong>of</strong> soil-water characteristic curve in-<br />

cluding initial drainage, main drainage <strong>an</strong>d imbibition curve as well as sc<strong>an</strong>ning curves the<br />

modified pressure plate apparatus was found to be the favorite equipment. Due to possibility<br />

<strong>of</strong> application <strong>of</strong> small suction increments the equipment enables precise determination <strong>of</strong> the<br />

shape <strong>of</strong> the soil-water characteristic curve during drainage <strong>an</strong>d imbibition. For investigation<br />

<strong>of</strong> influence <strong>of</strong> flow condition to the shape <strong>of</strong> the soil-water characteristic curve s<strong>an</strong>d column