PATIENT FOLLOW-UP:<br />
Have the patient:<br />
• Report immediately any difficulty in urinating<br />
• Report immediately any dis com fort<br />
• Return within 24 hours for first examination<br />
• Return for second examination within 3 days<br />
• Return for examination every 4 to 6 weeks<br />
Note: Above schedule of follow-up examinations may be altered to<br />
fit the needs of the individual patient.<br />
TO REMOVE:<br />
Hook one finger inside the center of<br />
the pessary. Use the thumb and<br />
middle finger to compress the side of<br />
the DONUT (see Figure 3). Use the<br />
finger of other hand to press down<br />
on the perineum. Angle the pessary<br />
and pull gently through the introitus<br />
(see Figure 1).<br />
Figure 3<br />
Note: If necessary, irrigate the vagina after removal of the pessary<br />
(and before reinsertion) to cleanse the vagina of excess discharge<br />
and secretions. HCPCS Supply Number A4320 (Irrigation Tray<br />
with Syringe, any purpose)<br />
During each visit, the vagina should be carefully inspected for<br />
evidence of pressure or allergic reaction. The patient should be<br />
questioned concerning discharge, disturbance of bowel function or<br />
difficulty in urinating. It may be necessary to fit another size or an<br />
entirely different shape pessary.<br />
DO NOT assume that a replacement will be the same size as the<br />
previous one. Check the fitting to ensure patient comfort and relief<br />
of symptoms.<br />
At each checkup, the pessary is removed and cleaned. If there are no<br />
contraindications, the pessary is reinserted.<br />