OPERATOR'S MANUAL FOR THE SYSTEM<br />

1 GENERAL INFORMATION<br />

1.1 THIS MANUAL<br />

The information in this <strong>manual</strong> is provided in eight sections and is intended for use<br />

with mobileMOSFET Software Versions 2.2 and above. After a general introduction,<br />

the instructions are laid out in the order of operation, with SYSTEM DESCRIPTION<br />

and SYSTEM SET-UP instructions followed by OPERATING PROCEDURE. This is<br />

followed by reference sections describing the System Components, Calibration and<br />

other key information.<br />

1.2 LABELING<br />

The following table defines the labeling symbols that may be found on certain<br />

mobileMOSFET <strong>system</strong> components and/or documentation.<br />

Manufacturer<br />

Date of manufacture (with date format of YYYY-MM)<br />

Authorized Representative for the European Union<br />

Consult Instructions<br />

SN Serial Number<br />

1.3 INTRODUCTION<br />

mobileMOSFET, model TN-RD-70-W, is <strong>Best</strong> <strong>Medical</strong> <strong>Canada</strong> Ltd's mobile, battery<br />

operated dose verification <strong>system</strong> intended for use in applications such as External<br />

Beam and Brachytherapy radiotherapy to verify treatment planning, and Radiology to<br />

measure dose uniformity and radiation exposure to the patient.<br />

The System consists of PC-based user-interface software and one or more<br />

mobileMOSFET Reader Modules. The Reader Module is small, lightweight, and<br />

battery-operated. It hosts the MOSFET dosimeters and realizes the measurement<br />

circuitry. The Software provides a console on screen for the operator to perform all<br />

required actions in dose measurements, such as reading, displaying, saving and<br />

printing results.<br />

The mobileMOSFET Remote Monitoring Dose Verification Software can be used to<br />

perform five treatment sessions simultaneously and each session can read up to eight<br />

readers. Note: Throughout this Manual, the term "Reader" refers to the<br />

mobileMOSFET Reader Module.<br />