28.02.2013 Views

3rd meeting of young researchers at UP 1 - IJUP - Universidade do ...

3rd meeting of young researchers at UP 1 - IJUP - Universidade do ...

3rd meeting of young researchers at UP 1 - IJUP - Universidade do ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Quantific<strong>at</strong>ion <strong>of</strong> Polycyclic Arom<strong>at</strong>ic Hydrocarbons in barbecued<br />

me<strong>at</strong> by HPLC/Fluorescence<br />

I. Mariano 1 , O. Viegas 1,2 , O. Pinho 1,2 , I.M.P.L.V.O. Ferreira 1<br />

1 REQUIMTE- Serviço de Brom<strong>at</strong>ologia, Faculdade de Farmácia da <strong>Universidade</strong> <strong>do</strong> Porto, Rua Anibal<br />

Cunha 164, 4099-030 Porto; Portugal<br />

2 Faculdade de Ciências da Nutrição e Alimentação da <strong>Universidade</strong> <strong>do</strong> Porto, Rua Dr. Roberto Frias,<br />

4200-465 Porto, Portugal<br />

Polycyclic arom<strong>at</strong>ic hydrocarbons (PAHs) are a group <strong>of</strong> about 10,000 compounds, a few <strong>of</strong><br />

which occur in considerable amounts in the environment and food. Due to their carcinogenic<br />

and mutagenic properties they are considered to be top <strong>of</strong> the list <strong>of</strong> the most hazar<strong>do</strong>us<br />

substances. Human beings are exposed to PAHs via air and drinking w<strong>at</strong>er, but mostly by<br />

intake <strong>of</strong> food, especially, charcoal grilled and smoked me<strong>at</strong> [1].<br />

The analysis <strong>of</strong> PAHs in food samples is hampered owing to their occurrence in food <strong>at</strong><br />

microtrace levels, i.e. ppb or ppt levels and the co-extraction <strong>of</strong> interfering compounds present<br />

in the complex food m<strong>at</strong>rices. Additionally, PAH are characterized by structural similarity and<br />

many occur as isomers, which again makes identific<strong>at</strong>ion <strong>of</strong> individual compounds extremely<br />

difficult. Thus, the challenge for its analysts is to maximize recovery <strong>of</strong> analyte and minimize<br />

the accompanying interferences by proper extraction and clean-up procedures.<br />

This work concerns the optimiz<strong>at</strong>ion <strong>of</strong> a method for determin<strong>at</strong>ion <strong>of</strong> PAHs in barbecued me<strong>at</strong><br />

by applic<strong>at</strong>ion <strong>of</strong> tandem solid-phase extraction (SPE) with columns filled with Extrelut<br />

di<strong>at</strong>omaceous earth, and column chrom<strong>at</strong>ography on silica gel for selective isol<strong>at</strong>ion <strong>of</strong> the 16<br />

PAHs highlighted by the US Environmental Protection Agency (EPA). Identific<strong>at</strong>ion and<br />

quantit<strong>at</strong>ive analysis <strong>of</strong> the individual compounds were achieved by HPLC/Fluorescence after<br />

separ<strong>at</strong>ion on a C18 column. Gradient elution was carried out with a mixture <strong>of</strong> three eluents:<br />

Eluent A was w<strong>at</strong>er/methanol (25:75), eluent B was methanol and eluent C was ethyl acet<strong>at</strong>e.<br />

The following gradient was used: 0–18 min, 100-20% A and 0-80% B; 18-19 min 20-0% A<br />

and 80-100% B; 19-20 min 100-90% B and 0-10% C; 20-28.5 min 90-82% B and 10-18% C;<br />

28.5-37.5min 82-80% B and 18-20% C; returning to initial conditions <strong>at</strong> 45 min and<br />

maintaining during 5 min., in a total run time <strong>of</strong> 50 min. The flow r<strong>at</strong>e was 1.0 mL/min. These<br />

conditions are a good altern<strong>at</strong>ive to the use <strong>of</strong> acetonitrile in the HPLC mobile phase [2] since<br />

it is a less expensive solvent for monitoriz<strong>at</strong>ion <strong>of</strong> PAHs. Additionally, experiments were<br />

carried out to determine maximum fluorescence excit<strong>at</strong>ion and emission wavelengths, to<br />

improve detection limits. The multistep clean-up procedure optimized, based on tandem solidphase<br />

extraction, in combin<strong>at</strong>ion with the chrom<strong>at</strong>ographic conditions selected enabled an<br />

accur<strong>at</strong>e and reproducible separ<strong>at</strong>ion <strong>of</strong> PAH fractions from the cooked me<strong>at</strong> samples.<br />

References:<br />

[1] Wenzl, T., Simon, R., Kleiner, J. and Anklam, E. (2006), Analytical methods for polycyclic<br />

arom<strong>at</strong>ic hydrocarbons (PAHs) in food and the environment needed for new food legisl<strong>at</strong>ion in the<br />

European Union. Trends in Analytical Chemistry, 25 (7), 716-725.<br />

[2] Janoszka, B., Warzecha, L., Błaszczyk, U. and Bodzek, D. (2004), Organic compounds formed in<br />

thermally tre<strong>at</strong>ed high-protein food. Part I: polycyclic arom<strong>at</strong>ic hydrocarbons. Acta chrom<strong>at</strong>ographica,<br />

14, 115-128.<br />

12 3 rd <strong>meeting</strong> <strong>of</strong> <strong>young</strong> <strong>researchers</strong> <strong>at</strong> <strong>UP</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!