fallen Pin deTeCTion adjUSTMenT<br />
The detection sensitivity level for pin fall can be adjusted in a range of 1 to 15. There is a sensitivity<br />
level adjusting gear for each of 10 pins. They are located at the front of the machine just above the<br />
string spools. Refer to Figure 4-5.<br />
The recommended sensitivity level setting is 10. The gears are marked every fifth tooth with numbers<br />
1, 5, 10, and 15.<br />
Figure 4-5. Fallen Pin Detection Adjustment<br />
1 SENSITIVITY LEVEL ADJUSTING GEAR<br />