(21) Main Power - Input power connection for the 3-phase power. This voltage can be 208, 220 or<br />

380V AC.<br />

(22) Stop1 - There are 2 stop switches on the machine. They are connected to Stop 1 in series<br />

(23) Stop2 - If this connection is open the machine will not operate. We use a jumper to close this<br />

connection. This could be used with a stop switch if desired.<br />

(24) Ball-Lift - This is a 24V AC supply for the ball lift relays. !NOTE: This is protect with at 250V<br />

0.1A fast blow fuse.<br />

(25) Elevator (Accelerator) - This provides three phase 380/220/208V power to the accelerator.<br />

(26) Engine - This provides three phase 380/220/208V power to the string pinsetter motor<br />

(27) Light - This provides single phase 220/208V power to the pin light.<br />

(28) Com Elevator ( Accelerator) - The odd and even control boxes of a lane pair are connected<br />

together at “Com Elevator”. The accelerator is connected to the odd lane control box. This is<br />

used to communicate from the even lane control box to operate the accelerator pinsetter.<br />