12<br />
when (H T ) > (V T )<br />
Simple venting configuration<br />
(only one 90° elbow)<br />
See graph to determine the required<br />
vertical rise V T for the required<br />
horizontal run H T .<br />
Example 4:<br />
V1 H1 H2 HR HO HT B<strong>CDV34</strong> & <strong>CDV34</strong> HORIZONTAL TERMINATION<br />
FIGURE 12<br />
REQUIRED<br />
VERTICAL<br />
RISE IN<br />
INCHES<br />
V T<br />
HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable<br />
values for H and V .<br />
T T<br />
For vent configurations requiring more than one 90° elbow<br />
the following formulas apply:<br />
Formula 1: H < 4.2 V T T<br />
Formula 2: H + V < 24.75 feet<br />
T T<br />
H1 H2 W415-0345 / L / 03.05.09<br />
V 1<br />
90°<br />
FIGURE 13<br />
= V = 6 ft<br />
T<br />
=3 ft<br />
=5 ft<br />
= H + H = 3 + 5 = 8 ft<br />
1 2<br />
= .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft<br />
= H + H = 8 + 2.7 = 10.7 ft<br />
R O<br />
H + V = 10.7 + 6 =16.7<br />
T T<br />
Formula 1: H < 4.2 V T T<br />
4.2 V = 4.2 x 6 = 25.2 ft<br />
T<br />
10.7 < 25.2<br />
Formula 2: H + V < 24.75 feet<br />
T T<br />
16.7 < 24.75<br />
Since both formulas are met, this vent configuration is acceptable.<br />
Example 5:<br />
V1 V2 VT H1 H2 H3 H4 HR HO HT V 1<br />
90°<br />
H 1<br />
=4 ft<br />
= 1.5 ft<br />
= V + V = 4 + 1.5 = 5.5 ft<br />
1 2<br />
=2 ft<br />
=1 ft<br />
=1 ft<br />
= 1.5 ft<br />
= H + H + H + H = 2 + 1 + 1 + 1. 5 = 5.5 ft<br />
1 2 3 4<br />
= .03(four 90° elbows - 90°) = .03(360° - 90°) = 8.1 ft<br />
= H + H = 5.5 + 8.1 = 13.6 ft<br />
R O<br />
H + V = 13.6 + 5.5 = 19.1 ft<br />
T T<br />
Formula 1:H T < 4.2 V T<br />
4.2 V T = 4.2 x 5.5 = 23.1 ft<br />
13.6 < 23.1<br />
Formula 2:H + V < 24.75 feet<br />
T T<br />
19.1 < 24.75<br />
90°<br />
H 2<br />
V2 H3 FIGURE 14<br />
H 4<br />
Since both formulas are met, this vent configuration is acceptable.