12<br />

when (H T ) > (V T )<br />

Simple venting configuration<br />

(only one 90° elbow)<br />

See graph to determine the required<br />

vertical rise V T for the required<br />

horizontal run H T .<br />

Example 4:<br />

V1 H1 H2 HR HO HT B<strong>CDV34</strong> & <strong>CDV34</strong> HORIZONTAL TERMINATION<br />

FIGURE 12<br />

REQUIRED<br />

VERTICAL<br />

RISE IN<br />

INCHES<br />

V T<br />

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable<br />

values for H and V .<br />

T T<br />

For vent configurations requiring more than one 90° elbow<br />

the following formulas apply:<br />

Formula 1: H < 4.2 V T T<br />

Formula 2: H + V < 24.75 feet<br />

T T<br />

H1 H2 W415-0345 / L / 03.05.09<br />

V 1<br />

90°<br />

FIGURE 13<br />

= V = 6 ft<br />

T<br />

=3 ft<br />

=5 ft<br />

= H + H = 3 + 5 = 8 ft<br />

1 2<br />

= .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft<br />

= H + H = 8 + 2.7 = 10.7 ft<br />

R O<br />

H + V = 10.7 + 6 =16.7<br />

T T<br />

Formula 1: H < 4.2 V T T<br />

4.2 V = 4.2 x 6 = 25.2 ft<br />

T<br />

10.7 < 25.2<br />

Formula 2: H + V < 24.75 feet<br />

T T<br />

16.7 < 24.75<br />

Since both formulas are met, this vent configuration is acceptable.<br />

Example 5:<br />

V1 V2 VT H1 H2 H3 H4 HR HO HT V 1<br />

90°<br />

H 1<br />

=4 ft<br />

= 1.5 ft<br />

= V + V = 4 + 1.5 = 5.5 ft<br />

1 2<br />

=2 ft<br />

=1 ft<br />

=1 ft<br />

= 1.5 ft<br />

= H + H + H + H = 2 + 1 + 1 + 1. 5 = 5.5 ft<br />

1 2 3 4<br />

= .03(four 90° elbows - 90°) = .03(360° - 90°) = 8.1 ft<br />

= H + H = 5.5 + 8.1 = 13.6 ft<br />

R O<br />

H + V = 13.6 + 5.5 = 19.1 ft<br />

T T<br />

Formula 1:H T < 4.2 V T<br />

4.2 V T = 4.2 x 5.5 = 23.1 ft<br />

13.6 < 23.1<br />

Formula 2:H + V < 24.75 feet<br />

T T<br />

19.1 < 24.75<br />

90°<br />

H 2<br />

V2 H3 FIGURE 14<br />

H 4<br />

Since both formulas are met, this vent configuration is acceptable.