26.03.2013 Views

CDV34 Gas Fireplace - Continental Fireplaces

CDV34 Gas Fireplace - Continental Fireplaces

CDV34 Gas Fireplace - Continental Fireplaces

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

14<br />

when (H ) > (V )<br />

T T<br />

Simple venting configurations<br />

See graph to determine the required vertical rise V T for the<br />

required horizontal run H T .<br />

MAXIMUM<br />

VERTICAL<br />

RISE IN<br />

FEET<br />

V T<br />

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable<br />

values for H and V .<br />

T T<br />

For vent configurations requiring more than two 90° elbow<br />

(top exit) or one 90° elbow (rear exit), the following formulas<br />

apply:<br />

Formula 1: H < 3V T T<br />

Formula 2: H + V < 40 feet<br />

T T<br />

Example 7:<br />

W415-0345 / L / 03.05.09<br />

B<strong>CDV34</strong> / <strong>CDV34</strong><br />

90°<br />

V 1<br />

H 1<br />

VERTICAL TERMINATION<br />

FIGURE 17<br />

BCDV33 / CDV33<br />

90°<br />

V 2<br />

FIGURE 18<br />

90°<br />

H 2<br />

V 3<br />

90°<br />

V1 V2 V3 VT H 1<br />

H 2<br />

HR HO =2 ft<br />

=1 ft<br />

=1.5 ft<br />

= V + V + V = 2 + 1 + 1.5 = 4.5 ft<br />

1 2 3<br />

=6 ft<br />

=2 ft<br />

= H + H = 6 + 2 = 8 ft<br />

1 2<br />

= .03(four 90° elbows - 90°)<br />

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft<br />

H =H + H = 8 + 8.1 = 16.1 ft<br />

T<br />

R O<br />

H + V = 16.1 + 4.5 = 20.6 ft<br />

T T<br />

Formula 1: H < 3V T T<br />

3V = 3 x 4.5 = 13.5 ft<br />

T<br />

16.1 > 13.5<br />

Since this formula is not met, this vent configuration is unacceptable.<br />

Formula 2: H + V < 40 feet<br />

T T<br />

20.6 < 40<br />

Since only formula 2 is met, this vent configuration is unacceptable<br />

and a new fireplace location or vent configuration<br />

will need to be established to satisfy both formulas.<br />

Example 8:<br />

V1 V2 VT H 1<br />

H 2<br />

H 3<br />

HR HO H 1<br />

90°<br />

V 1<br />

H 2<br />

90°<br />

45°<br />

H 3<br />

FIGURE 19<br />

V 2<br />

=1.5 ft<br />

=5 ft<br />

= V + V = 1.5 + 5 = 6.5 ft<br />

1 2<br />

=1 ft<br />

=1 ft<br />

=10.75 ft<br />

= H + H + H = 1 + 1 + 10.75 = 12.75 ft<br />

1 2 3<br />

= .03(three 90° elbows + one 45° elbow - 90°)<br />

= .03(90 + 90 + 90 + 45 - 90) = 6.75 ft<br />

H =H + H = 12.75 + 6.75 = 19.5 ft<br />

T<br />

R O<br />

H + V = 19.5 + 6.5 = 26 ft<br />

T T<br />

90°<br />

Formula 1: H < 3V T T<br />

3V = 3 x 6.5 = 19.5 ft<br />

T<br />

19.5 = 19.5<br />

Formula 2: H + V < 40 feet<br />

T T<br />

26 < 40<br />

Since both formulas are met, this vent configuration is acceptable.