Executive Summary<br />

General Description<br />

<strong>Sitka</strong> Harbors operates <strong>and</strong> maintains seven upl<strong>and</strong> buildings including, five restrooms, one<br />

harbormaster/shop building, <strong>and</strong> one net shed. The restroom buildings are located at the O’Connell Bridge<br />

Lightering Float, Sealing Cove Harbor, ANB Harbor, Thomsen Harbor, <strong>and</strong> Eliason Harbor. The restrooms<br />

at Crescent Harbor are operated <strong>and</strong> maintained by the CBS Parks <strong>and</strong> Recreation Department <strong>and</strong> not<br />

included in this study. The net shed is located at the west end <strong>of</strong> Crescent Harbor.<br />

General Condition<br />

All buildings are wood frame construction with concrete footings <strong>and</strong> range in age from 10 to 35 years old.<br />

These are high use facilities on <strong>Sitka</strong>’s waterfront. The typical life expectancy for similar use <strong>and</strong> construction<br />

type public restrooms in a waterfront environment is 30 to 40 years. Overall, facilities in <strong>Sitka</strong> have been very<br />

well maintained <strong>and</strong> are in good condition despite being at or near their typical life expectancy. Immediate<br />

<strong>and</strong> short term actions were identified for each facility. Immediate actions are upgrades <strong>and</strong> repairs that<br />

address a condition related to health <strong>and</strong> safety or a condition contributing to system failure. Short-term<br />

upgrades <strong>and</strong> repairs include preventative maintenance.<br />

Estimated Required Expenditures<br />

Cost estimates have been prepared for in kind replacement <strong>of</strong> the existing facilities. A square footage<br />

construction cost is applied to each facility. All facilities remained the same size; with the exception <strong>of</strong><br />

Eliason restroom which was increased by approximately 10% because it was identified as undersized.<br />

Indirect costs are not included in these estimates.<br />

Table 1. Estimated Expenditures Summary<br />

93<br />

<strong>Sitka</strong> Harbor System Master Plan<br />