Output Tests cont. - Section 18-B<br />

On most systems, the Output Tests function is only available when the Engine is not<br />

running.<br />

It is perfectly normal to see a "short to ground" message in the process of running Output<br />

Tests. The ECU identifies which output it is currently testing by sending a fault-code<br />

number. On many ECUs the full text for this fault code includes "short to ground". Why?<br />

Because one side of the actuator in question has 12V on it all the time and the ECU<br />

completes the circuit (and turns the actuator on) by pulling the other side to ground.<br />

Warning:<br />

Do not use the Output Tests function on any system while the car is in motion! Running<br />

Output Tests on the ABS brake system can temporarily disable the brakes entirely and<br />

cause individual wheels to lock and unlock.<br />

We strongly suggest you refer to the Factory Repair <strong>Manual</strong> for your specific car<br />

before running Output Tests on any Control Module so you will know what to expect!<br />

If you try to perform Output Tests on an Airbag controller, the following warning will pop up:<br />

For example, in the VW Touareg, a specific procedure must be performed to be able to<br />

start the vehicle if Output Tests on the Airbag Controller have been performed.