The <strong>ES7000</strong> <strong>Model</strong> <strong>7600R</strong> <strong>G2</strong> Server<br />

The DSA Preboot diagnostic programs are stored in integrated USB memory <strong>and</strong><br />

collect <strong>and</strong> analyze system information to aid in diagnosing server problems. The<br />

diagnostic programs collect the following information about the server:<br />

- Event logs for ServeRAID controllers <strong>and</strong> service processors<br />

- Hard disk drive health<br />

- Installed hardware<br />

- Light path diagnostics status<br />

- Network interfaces <strong>and</strong> settings<br />

- RAID controller configuration<br />

- Service processor status <strong>and</strong> configuration<br />

- System configuration<br />

- Vital product data, firmware, <strong>and</strong> UEFI configuration<br />

For additional information about DSA, see the Problem Determination <strong>and</strong> Service<br />

<strong>Guide</strong>.<br />

• Redundant connection<br />

The addition of an optional network interface card (NIC) provides a failover capability to<br />

a redundant Ethernet connection. If a problem occurs with the primary Ethernet<br />

connection, all Ethernet traffic that is associated with the primary connection is<br />

automatically switched to the redundant NIC. If the applicable device drivers are<br />

installed, this switching occurs without data loss <strong>and</strong> without user intervention.<br />

• Redundant cooling <strong>and</strong> power capabilities<br />

The redundant cooling of the fans in the server enables continued operation if one of<br />

the fans fails. The server supports two hot-swap power supplies, which provide<br />

redundant power when connected to a 208-240v source.<br />

• ServeRAID support<br />

The server supports ServeRAID controllers to create redundant array of<br />

independent disks (RAID) configurations.<br />

• Symmetric multiprocessing (SMP)<br />

The server supports up to four multi-core Intel Xeon microprocessors. One or more<br />

multi-core microprocessors provides SMP capability.<br />

Reliability, availability, <strong>and</strong> serviceability<br />

Three important server design features are reliability, availability, <strong>and</strong> serviceability (RAS).<br />

The RAS features help to ensure the integrity of the data that is stored in the server, the<br />

availability of the server when you need it, <strong>and</strong> the ease with which you can diagnose <strong>and</strong><br />

correct problems.<br />

The server has the following RAS features:<br />

2–10 3850 7273–001