13.1.5 Au<strong>to</strong>matic Operation<br />

This mode can be set using remote control and the operation is decided by remote control setting temperature,<br />

remote control operation mode and indoor intake air temperature.<br />

During operation mode judgment, indoor fan mo<strong>to</strong>r (with speed of Lo-) is running for 30 seconds <strong>to</strong> detect the<br />

indoor intake air temperature.<br />

Every 10 minutes, the indoor temperature is judged.<br />

For the 1st judgment<br />

o If indoor intake temperature - remote control setting temperature ≥ 2°C, COOL mode is decided.<br />

o If -2°C ≤ indoor intake temperature - remote control setting temperature < 2°C, DRY mode is decided.<br />

o If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.<br />

For the 2nd judgment onwards<br />

o If indoor intake temperature - remote control setting temperature ≥ 3°C, if previous operate in DRY mode,<br />

then continue in DRY mode. otherwise COOL mode is decided.<br />

o If -2°C ≤ indoor intake temperature - remote control setting temperature < 3°C, maintain with previous mode.<br />

o If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.<br />

13.1.6 Fan Operation<br />

Fan operation is used <strong>to</strong> circulate air in the room.<br />

During operation, indoor fan run continuously but outdoor fan and compressor s<strong>to</strong>p.<br />

Temperature setting is not applicable.<br />

13.2 Indoor Fan Mo<strong>to</strong>r Operation<br />

13.2.1 Basic Rotation Speed (rpm)<br />

<strong>Manual</strong> Fan Speed<br />

[Cooling, Dry]<br />

o Fan mo<strong>to</strong>r’s number of rotation is determined according <strong>to</strong> remote control setting.<br />

Remote control ○ ○ ○ ○ ○<br />

Tab Hi Me+ Me Me- Lo<br />

[Heating]<br />

o Fan mo<strong>to</strong>r’s number of rotation is determined according <strong>to</strong> remote control setting.<br />

Remote control ○ ○ ○ ○ ○<br />

Tab SHi Me+ Me Me- Lo<br />

Au<strong>to</strong> Fan Speed<br />

[Cooling, Dry]<br />

o According <strong>to</strong> room temperature and setting temperature, indoor fan speed is determined au<strong>to</strong>matically.<br />