o The indoor fan will operate according <strong>to</strong> pattern below.<br />

[Heating]<br />

o According <strong>to</strong> indoor pipe temperature, au<strong>to</strong>matic heating fan speed is determined as follows.<br />

13.2.2 Feedback control<br />

Immediately after the fan mo<strong>to</strong>r started, feedback control is performed once every second.<br />

During fan mo<strong>to</strong>r on, if fan mo<strong>to</strong>r feedback ≥ 2550 rpm or < 50 rpm continue for 10 seconds, then fan mo<strong>to</strong>r error<br />

counter increase, fan mo<strong>to</strong>r is then s<strong>to</strong>p and restart. If the fan mo<strong>to</strong>r counter becomes 7 times, then H19 - fan<br />

mo<strong>to</strong>r error is detected. Operation s<strong>to</strong>ps and cannot on back.<br />

13.3 Outdoor Fan Mo<strong>to</strong>r Operation<br />

Outdoor fan mo<strong>to</strong>r is operated with one fan speed only. It starts when compressor starts operation and it s<strong>to</strong>ps 30<br />

seconds after compressor s<strong>to</strong>ps operation.<br />