Remote Control Receiving Sound<br />

o Normal Operation nanoe-G Operation : Beep<br />

o Nanoe-G Operation Normal Operation : Beep<br />

o S<strong>to</strong>p nanoe-G individual Operation : Beep<br />

o Nanoe-G individual Operation S<strong>to</strong>p : Long Beep<br />

Power failure<br />

o During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual<br />

operation resumes immediately.<br />

o During combination operation, if power failure occurs, after power resumes, combination operation resume<br />

immediately.<br />

o nanoe-G operation status is not memorized after OFF the unit. After OFF the unit, when the operation is ON<br />

again, air conditioner operates without nanoe-G operation.<br />

nanoe-G check mode<br />

o To enable nanoe-G check mode, during nanoe-G operation ON:<br />

o If there is abnormal discharge, nanoe-G indica<strong>to</strong>r blinks immediately.<br />

Error detection control<br />

When nanoe-G indica<strong>to</strong>r blinks, it indicates error listed below:<br />

o nanoe-G connec<strong>to</strong>r at main PCB open<br />

Judgment method<br />

During nanoe-G operation, nanoe-G connec<strong>to</strong>r at main PCB is opened.<br />

Troubleshooting method<br />

Connect the connec<strong>to</strong>r or s<strong>to</strong>p operation <strong>to</strong> cancel the blinking<br />

o Abnormal discharge error<br />

Judgment method<br />

During nanoe-G operation, the nanoe-G system has abnormal discharge due <strong>to</strong> short-circuit caused<br />

by water or dust adhesion and so forth, with Lo-feedback voltage (at microcontroller).<br />

When abnormal discharge occurred, every 30 minutes the unit supplies power <strong>to</strong> the nanoe-G<br />

system.<br />

When abnormal discharge occurs for 24 times continuously, nanoe-G indica<strong>to</strong>r blinks.<br />