E9 to E28 NKR Service Manual.pdf - Industrial Air
E9 to E28 NKR Service Manual.pdf - Industrial Air
E9 to E28 NKR Service Manual.pdf - Industrial Air
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Remote Control Receiving Sound<br />
o Normal Operation nanoe-G Operation : Beep<br />
o Nanoe-G Operation Normal Operation : Beep<br />
o S<strong>to</strong>p nanoe-G individual Operation : Beep<br />
o Nanoe-G individual Operation S<strong>to</strong>p : Long Beep<br />
Power failure<br />
o During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual<br />
operation resumes immediately.<br />
o During combination operation, if power failure occurs, after power resumes, combination operation resume<br />
immediately.<br />
o nanoe-G operation status is not memorized after OFF the unit. After OFF the unit, when the operation is ON<br />
again, air conditioner operates without nanoe-G operation.<br />
nanoe-G check mode<br />
o To enable nanoe-G check mode, during nanoe-G operation ON:<br />
o If there is abnormal discharge, nanoe-G indica<strong>to</strong>r blinks immediately.<br />
Error detection control<br />
When nanoe-G indica<strong>to</strong>r blinks, it indicates error listed below:<br />
o nanoe-G connec<strong>to</strong>r at main PCB open<br />
Judgment method<br />
During nanoe-G operation, nanoe-G connec<strong>to</strong>r at main PCB is opened.<br />
Troubleshooting method<br />
Connect the connec<strong>to</strong>r or s<strong>to</strong>p operation <strong>to</strong> cancel the blinking<br />
o Abnormal discharge error<br />
Judgment method<br />
During nanoe-G operation, the nanoe-G system has abnormal discharge due <strong>to</strong> short-circuit caused<br />
by water or dust adhesion and so forth, with Lo-feedback voltage (at microcontroller).<br />
When abnormal discharge occurred, every 30 minutes the unit supplies power <strong>to</strong> the nanoe-G<br />
system.<br />
When abnormal discharge occurs for 24 times continuously, nanoe-G indica<strong>to</strong>r blinks.<br />
87