13.10 Indication Panel<br />
LED POWER TIMER POWERFUL nanoe-G AUTO COMFORT QUIET<br />
Color Green Orange Orange Blue Green Green<br />
Light ON Operation ON Timer Setting ON<br />
Light OFF Operation OFF Timer Setting OFF<br />
POWERFUL Mode<br />
ON<br />
POWERFUL Mode<br />
OFF<br />
86<br />
nanoe-G ON<br />
nanoe-G OFF<br />
AUTO COMFORT<br />
ON<br />
AUTO COMFORT<br />
OFF<br />
QUIET Mode<br />
ON<br />
QUIET Mode<br />
OFF<br />
Note:<br />
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation<br />
mode judgment, or ON timer sampling.<br />
If Timer LED is blinking, there is an abnormality operation occurs.<br />
13.11 nanoe-G Operation<br />
This operation provides clean air by producing great amount of negative ions and distribute through the<br />
discharge airflow <strong>to</strong> capture or deactivate molds, bacteria or viruses.<br />
nanoe-G operation start condition<br />
o During unit running at any operation mode, if nanoe-G operation is activated, combination operation<br />
(operation mode + nanoe-G operation) starts.<br />
o During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.<br />
nanoe-G operation s<strong>to</strong>p condition<br />
o When OFF/ON but<strong>to</strong>n is pressed <strong>to</strong> s<strong>to</strong>p the operation.<br />
o When nanoe-G but<strong>to</strong>n is pressed.<br />
o When OFF Timer activates.<br />
nanoe-G operation pause condition<br />
o When indoor fan s<strong>to</strong>p (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after<br />
indoor fan restarts.<br />
o When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°C<br />
continuously for 30 minutes.<br />
Indoor fan control<br />
o During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.<br />
However, nanoe-G system enabled when fan speed ≥ 500rpm <strong>to</strong> ensure proper negative ion distribution,<br />
nanoe-G system disabled when fan speed < 500 rpm.<br />
o During nanoe-G individual operation, only Au<strong>to</strong> Fan Speed and no Powerful operation is allowed. Even if Fan<br />
Speed but<strong>to</strong>n is pressed, no signal is sent <strong>to</strong> the unit and no change on remote control display. Au<strong>to</strong> Fan<br />
Speed for nanoe-G operation changes from SHi <strong>to</strong> Hi after 4 hours of operation.<br />
<strong>Air</strong>flow direction control<br />
o During any operation mode combines with nanoe-G operation, airflow direction follows respective operation<br />
mode.<br />
o During nanoe-G individual operation, only Au<strong>to</strong> <strong>Air</strong> Swing is allowed. Even if <strong>Air</strong> Swing but<strong>to</strong>n is pressed, no<br />
signal is sent <strong>to</strong> the unit and no change on remote control display.<br />
Timer control<br />
o When ON Timer activates when unit s<strong>to</strong>ps, previous operation resumes and res<strong>to</strong>red last saved nanoe-G<br />
operation status.<br />
o When ON Timer activates during any operation, no change on current operation.<br />
o When OFF Timer activates during any operation, all operation s<strong>to</strong>ps and the latest nanoe-G operation status<br />
is saved.<br />
Indica<strong>to</strong>r<br />
o When nanoe-G starts, nanoe-G indica<strong>to</strong>r ON.