Potential Pollutant Linkages<br />

7.33 The potential pollutant linkages are assessed below:<br />

Contamination<br />

Source<br />

Contaminants<br />

associated with<br />

made ground on<br />

site –<br />

Hydrocarbons<br />

Ground gases –<br />

deep made<br />

ground or off<br />

site refuse tip<br />

Contaminants<br />

from off-site<br />

sources e.g.<br />

garage<br />

Pathway Hazard Potential<br />

Receptors<br />

Direct contact,<br />

ingestion, dust<br />

inhalation<br />

Direct contact,<br />

ingestion, dust<br />

inhalation<br />

Lateral and<br />

vertical migration<br />

Lateral and<br />

vertical migration<br />

Lateral and<br />

vertical migration<br />

and inhalation<br />

Direct contact,<br />

ingestion, dust<br />

and vapour<br />

inhalation<br />

Human health<br />

risk<br />

Human health<br />

risk<br />

Pollution of the<br />

water<br />

environment<br />

Human health<br />

risk<br />

Human health<br />

risk<br />

Human health<br />

risk<br />

Site construction<br />

workers<br />

Linkage Complete<br />

Yes, can be removed by the use<br />

of appropriate PPE and limited<br />

exposure.<br />

Site end users Yes, there is a possible risk to site<br />

end users but this will be<br />

mitigated by the presence of<br />

buildings or hardstanding over<br />

much of the site.<br />

Aquifer and<br />

Espedair Burn<br />

Adjacent<br />

properties<br />

Possible but unlikely. No known<br />

groundwater abstractions present.<br />

River. No groundwater recorded<br />

within the reservoir area in the<br />

trial pits, indicating flow is<br />

negligible.<br />

No. Predominantly commercial<br />

properties in the direction of<br />

groundwater flow. Surrounding<br />

area is covered by glacial till.<br />

Site end users Yes, mitigated by monitoring or<br />

incorporation of gas membrane<br />

Site end users No contamination identified likely<br />

to arise from off-site sources<br />

7.34 In summary, based on an assessment of the chemical results, the site presents a low<br />

risk to site end users in view of the commercial nature of the development; all the site area<br />

will be covered by hardstanding or buildings. Some TPH and PAH has been recorded in<br />

groundwater within the backfilled reservoir, which could pose a potential migration risk.<br />