<strong>SGC</strong> Rapport 2013:270<br />

With a suitable refrigerant mix, very high temperature drops can be realised which<br />

otherwise would require a cascade cycle with multiple steps. Furthermore, it is<br />

possible to use only one refrigerant pump for the whole process, as opposed to a<br />

cascade process where each step needs its own pump. However, MRC processes<br />

require much more know-how and are more sophisticated than single refrigerant<br />

cycles, so the development costs are higher too. This makes it difficult to deploy<br />

MRC processes for the relatively small-scale biogas applications.<br />

80 Svenskt Gastekniskt Center AB, Malmö <strong>–</strong> www.sgc.se