2 OPERATION PT / PG / PD REPAIR<br />
2.4 Starting / Stopping (cont.)<br />
PTS4V<br />
1. Open fuel valve (a 1 ).<br />
2. If engine is cold, pull choke control out (b 1 ). If engine<br />
is hot, push choke control in (b 2 ).<br />
3. Move throttle control to the fast position (c 1 ).<br />
4. Turn key switch to the start position (d ) and hold until<br />
3<br />
engine starts.<br />
CAUTION: Do not crank engine longer than 15 seconds<br />
at a time. Extended cranking can damage starter motor.<br />
5. To start engine using manual start: Turn key switch to<br />
the run position (d 2 ). Pull starter rope (e) rapidly to<br />
start engine.<br />
Leave key in run position (d ) while engine is running.<br />
2<br />
Note: The engine is equipped with a low oil protection<br />
system. If the oil level is low, the engine will not start.<br />
Check engine oil level if engine does not start.<br />
6. Push choke in as engine warms (b ). 2<br />
7. Keep engine throttle in the fast position while operating<br />
pump.<br />
2-10<br />
b 1<br />
c 1<br />
c 2<br />
b 2<br />
e<br />
To Stop<br />
1. Reduce engine RPM by moving throttle completely to<br />
the idle position (c 2 ).<br />
2. Turn engine switch to the stop position (d 1 ).<br />
3. Close fuel valve (a 2 ).<br />
a 2<br />
a 1<br />
d 1<br />
d 2<br />
d 3<br />
1020SD71