4 PG SERIES PUMPS PT / PG / PD REPAIR<br />

4.3 Air Cleaner<br />

Service air cleaner frequently to prevent carburetor malfunction.<br />

CAUTION: NEVER run engine without air cleaner.<br />

Severe engine damage will occur.<br />

WARNING<br />

NEVER use gasoline or other types of low flash<br />

point solvents for cleaning the air cleaner. A fire or<br />

explosion could result.<br />

To service:<br />

1. Remove air cleaner cover (a). Inspect element (b) for<br />

holes or tears. Replace element if damaged.<br />

2. Wash element in solution of mild detergent and warm<br />

water. Rinse thoroughly in clean water. Allow element<br />

to dry thoroughly.<br />

4.4 Engine Oil<br />

Drain oil while engine is still warm.<br />

1. Remove oil fill plug (d) and drain plug (e) to drain oil.<br />

2. Install drain plug.<br />

3. Fill engine crankcase with recommended oil up to<br />

level of plug opening (f).<br />

4-4<br />

Soak element in clean engine oil and squeeze out<br />

excess oil.<br />

3. Install element, grid plate (c), and air cleaner cover.<br />

Oil capacity: 20 oz. (0.6 liters)<br />

4. Install oil filler plug.<br />

a<br />

b<br />

c<br />

e<br />

d<br />

1020SD13<br />

f<br />

1005SD53